Automated and conventional ABR screening techniques in high-risk infants.

نویسندگان

  • J T Jacobson
  • C A Jacobson
  • R C Spahr
چکیده

Test validity is determined by the proportion of results that are diagnostically confirmed and predicted on the measures used to identify the disease process. This article summarizes the results of a series of 224 stable high-risk infants who were screened by automated (ALGO-1) and conventional (Bio-logics LT) ABR instrumentation. Failure criteria was defined as the absence or prolongation of a replicable wave V response (conventional) or Refer by the automated system. The overall failure rates at a 35 dB screening level were comparable between devices. Sensitivity and specificity measures for the ALGO-1 unit were 100 and 96 percent, respectively. Permanent hearing loss was demonstrated in 5 percent of the newborns screened in this study. Advantages of the automated system include a dual artifact rejection system, attenuating ear couplers, and a battery operated design. These findings suggest that the automated ABR screener is a viable alternative to conventional ABR instrumentation for the limited purpose of neonatal auditory screening.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity of the Automated Auditory Brainstem Response in Neonatal Hearing Screening.

BACKGROUND In a 2-stage neonatal hearing screening protocol, if an infant fails the first-stage abstract screening with an otoacoustic emissions test, an automated auditory brainstem response (ABR)test is performed. The purpose of this study was to estimate the rate of hearing loss detected byfirst-stage otoacoustic emissions test but missed by second-stage automated ABR testing. METHODS The ...

متن کامل

A multisite study to examine the efficacy of the otoacoustic emission/automated auditory brainstem response newborn hearing screening protocol: research design and results of the study.

PURPOSE Most newborns are screened for hearing loss, and many hospitals use a 2-stage protocol in which all infants are screened first with otoacoustic emissions (OAEs). In this protocol, no additional testing is done for those passing the OAE screening, but infants failing the OAE are also screened with automated auditory brainstem response (A-ABR). This study evaluated how many infants who fa...

متن کامل

Recovery of Abnormal ABR in Neonates and Infants at Risk of Hearing Loss

The purpose of this retrospective study is to present the clinical experience of a single institution on the recovery of ABR thresholds in a large population of neonates and infants at risk of hearing loss. Potential prognostic factors associated with this phenomenon were also investigated. Out of 2248 high risk infants, 384 had abnormal ABR at initial hearing evaluation and 168 of them had abs...

متن کامل

Neonatal Screening for Hearing Loss Using OAE and Comparison it with Conventional Methods

Introduction: Communication is the essence of life. Speech, Language and Hearing are involved rigorously in any communication around us. Children Hearing loss in children constitutes a considerable handicap because it is an invisible disability & compromises optimal development & personnel achievement of a child. Screening is one of the most important methods for early diagnosis of hearing loss...

متن کامل

بررسی شنوایی‌سنجی (ABR) نوزادان ترم سالم بستری با بیلی‌روبین بالای در حد تعویض خون

Background and Objective: Hyperbilirubinemia is a common neonatal abnormality. Severe hyperbilirubinemia is a risk factor for auditory system injury. Auditory brainstem responses (ABR) are important in early diagnosis of hearing impairments in healthy term infants with elevated bilirubin levels requiring exchange transfusion. Materials and Methods: During a two- year- period (2007 – 2009), in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 1 4  شماره 

صفحات  -

تاریخ انتشار 1990