An evaluation of two aerosol delivery systems for rhDNase.

نویسندگان

  • P L Shah
  • S F Scott
  • D M Geddes
  • S Conway
  • A Watson
  • T Nazir
  • S B Carr
  • C Wallis
  • C Marriott
  • M E Hodson
چکیده

Increasingly, proteins are delivered to the respiratory tract as an aerosol, and clinical efficacy is dependent on optimal delivery of the protein in an intact form. The object of this study was to compare the in vivo and in vitro results of two aerosol delivery systems for the aerosolization of recombinant human deoxyribonuclease I (rhDNase) in patients with cystic fibrosis (CF). Patients with CF who were to be initiated on rhDNase were randomized either to the Hudson nebulizer and Pulmo-Aide compressor or to the Sidestream nebulizer driven by the CR50 air compressor. An in vitro study was performed in six sets of the two aerosol delivery systems. One hundred and seventy three patients were randomized in this open study, where rhDNase was administered for 7 days. Improvements in pulmonary function were observed in both groups following 1 week of therapy with rhDNase. Changes in the Sidestream/CR50 and Hudson/Pulmo-Aide groups, respectively, were: 16 and 11% for forced expiratory volume in one second (p=0.14); 12 and 10% for forced vital capacity (p=0.70); and 14 and 7% for forced expiratory flow at 25-75% of expiration (FEF(25-75)) (p=0.18). A greater proportion of patients in the Sidestream/CR50 group (58%) had a >10% response in FEF(25-75) compared to the Hudson/Pulmo-Aide group (42%; p=0.03). The Sidestream nebulizer had a faster nebulization rate (p<0.05), lower mass median diameter for the aerosol mass produced (p<0.001), higher percentage of particles in the respirable range (p<0.001) and greater respirable output (p<0.005), compared to the Hudson nebulizer. The Sidestream/CR50 combination is a quicker, more efficient system in vitro than the Hudson/Pulmo-Aide combination, whereas the in vivo study only suggested a difference. Clinically, the two systems have similar efficacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aerosol delivery of recombinant human DNase I: in vitro comparison of a vibrating-mesh nebulizer with a jet nebulizer.

BACKGROUND Inhaled recombinant human DNase I (rhDNase) improves clearance of visco-elastic secretions in patients with cystic fibrosis. Because of their portability, newer-generation vibrating-mesh nebulizers offer greater convenience for the patient, but their efficiency in delivering rhDNase has not been determined. METHODS We compared a newer-generation vibrating-mesh nebulizer (Omron Micr...

متن کامل

New liquid aerosol generation devices: systems that force pressurized liquids through nozzles.

Over the past few decades, aerosol delivery devices have been relatively inefficient, wasteful, and difficult for patients to use. These drawbacks have been tolerated because the drugs available for inhalation have wide therapeutic margins and steep dose-response curves at low doses. Recently several forces have converged to drive innovation in the aerosol device industry: the ban on chlorofluo...

متن کامل

A Review on the Evaluation Methods of Health Information Systems

Evaluation of health information systems is an effective approach to ensure the efficacy of the system which can lead to the improvement in quality of health care services. The main aims of evaluation are to identify the strength and efficiency of system in health care delivery, to identify the weaknesses of the system, and to suggest general recommendations for improving the performance of the...

متن کامل

Gamma scintigraphy in the evaluation of drug delivery systems [Persian]

Gamma-scintigraphy is applied extensively in the development and evaluation of pharmaceutical delivery systems, particularly for monitoring formulations in the gastrointestinal and respiratory tracts. The radiolabelling is generally achieved by the incorporation of an appropriate radionuclide such as technetium-99m or indium-111 into the formulation or by addition of a non-radioactive iso...

متن کامل

Gene Expression and Pulmonary Toxicity of Chitosan-graft-Polyethylenimine as Aerosol Gene Carrier

Chitosan-graft-polyethylenimine (CHI-g-PEI) copolymer has been used for theimprovement of low transfection efficiency of chitosan. The present study aims to test thepulmonary toxicity and efficiency of CHI-g-PEI as an aerosol gene carrier. Mice were exposedto aerosol containing green-fluorescent protein (GFP)-polyethylenimine (PEI) or GFP-CHIg-PEI complexes for 30 min during the development of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 1997