Comparison of anterior cervical discectomy and fusion with the zero-profile implant and cage-plate implant in treating two-level degenerative cervical spondylosis

نویسندگان

  • Yi Yang
  • Litai Ma
  • Junfeng Zeng
  • Hao Liu
  • Ying Hong
  • Beiyu Wang
  • Chen Ding
  • Yuxiao Deng
  • Yueming Song
چکیده

Previous studies based on small sample sizes have reported the application of the Zero-P implant (Zero-P, Synthes GmbH, Switzerland) in single anterior cervical discectomy and fusion (ACDF) surgery with excellent outcomes. However, the safety and effectiveness of two-level ACDF with Zero-P implant still remains controversial. A retrospective study was conducted to compare the clinical outcomes and complications between Zero-P implant and conventional cage-plate implant in two-level ACDF for the treatment of degenerative cervical spondylosis. The Japanese Orthopedic Association (JOA) scale score, neck and arm visual analog scale (VAS), bony fusion rates and main complications were recorded. Dysphagia was evaluated according to the Bazaz grading system. A total of 67 consecutive patients in Zero-P group and 72 consecutive patients in Plate group were enrolled in this retrospective study. The total incidence of dysphagia in Zero-P group and Plate group were 40.00% and 55.56% at one week, respectively. Similar improvements were observed in the JOA and VAS pain scores in both groups at the final follow-up (P>0.05). There were no significant difference between two groups concerning other complications such as postoperative hematoma, recurrent laryngeal nerve palsy, cerebrospinal fluid leakage and pseudarthrosis. The Zero-P implant and the traditional titanium plate with cage are both effective treatments for two-level degenerative cervical spondylosis, but the Zero-P implant has a lower dysphagia incidence. Future prospective, randomized and controlled studies with larger sample size are needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Zero-profile implant versus conventional cage-plate implant in anterior cervical discectomy and fusion for the treatment of degenerative cervical spondylosis: a meta-analysis

BACKGROUND Zero-profile implant has become more and more popular in anterior cervical discectomy and fusion (ACDF) for the treatment of degenerative cervical spondylosis. However, there was no enough evidence judging its efficiency and safety. The aim of this analysis was to evaluate the efficacy and safety of Zero-profile implant compared with conventional cage-plate (CCP) in ACDF. METHODS A...

متن کامل

Comparison among perfect-C®, zero-P®, and plates with a cage in single-level cervical degenerative disc disease

BACKGROUND We intended to analyze the efficacy of a new integrated cage and plate device called Perfect-C for anterior cervical discectomy and fusion (ACDF) to cure single-level cervical degenerative disc disease. METHODS We enrolled 148 patients who were subjected to single-level ACDF with one of the following three surgical devices: a Perfect-C implant (41 patients), a Zero-P implant (36 pa...

متن کامل

The new Zero-P implant can effectively reduce the risk of postoperative dysphagia and complications compared with the traditional anterior cage and plate: a systematic review and meta-analysis

BACKGROUND The low-profile angle-stable spacer Zero-P is a new kind of cervical fusion system that is claimed to limit the potential drawbacks and complications. The purpose of this meta-analysis was to compare the clinical and radiological results of the new Zero-P implant with those of the traditional anterior cage and plate in the treatment of symptomatic cervical spondylosis, and provides c...

متن کامل

Outcome Evaluation of Zero-Profile Implant Compared with an Anterior Plate and Cage Used in Anterior Cervical Discectomy and Fusion: A Two-Year Follow-Up Study.

AIM To compare the clinical outcome and complications between Zero-P implant and cage with anterior plate in patients undergoing anterior cervical discectomy and fusion (ACDF). MATERIAL AND METHODS 50 patients underwent ACDF operation of which 23 patients had Zero-P implanted and 27 had cage and plate implanted. Preoperative and Post-operative clinical evaluation included Japanese Orthopaedic...

متن کامل

Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion

Background:   After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use   of hydroxyapatite granules as a substitute for autograft for interbody fusion.     Methods:   From November 2008 to November 2011, 236 patients participated in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016