Alternative light source (polilight) illumination with digital image analysis does not assist in determining the age of bruises.
نویسندگان
چکیده
The age of a bruise may be of interest to forensic investigators. Previous research has demonstrated that an alternative light source may assist in the visualisation of faint or non-visible bruises. This project aimed to determine if an alternative light source could be utilised to assist investigators estimate the age of a bruise. Forty braises, sustained from blunt force trauma, were examined from 30 healthy subjects. The age of the bruises ranged from 2 to 231 h (mean = 74.6, median = 69.0). Alternative light source (polilight) illumination at 415 and 450 nm was used. The black and white photographs obtained were assessed using densitometry. A statistical analysis indicated that there was no correlation between time and the mean densitometry values. The alternative light source used in this study was unable to assist in determining the age of a bruise.
منابع مشابه
The use of Polilight in the detection of seminal fluid, saliva, and bloodstains and comparison with conventional chemical-based screening tests. J Forensic Sci 2006;51(2):361-70.
Biological stains can be difficult to detect at crime scenes or on items recovered from crime scenes. The use of a versatile light source may assist in their detection. The ability of Polilight to locate potential semen, saliva, and blood stains on a range of substrates and at different dilutions was tested. We also tested the use of Polilight in comparison with conventional chemical-based pres...
متن کاملNovel Automated Method for Minirhizotron Image Analysis: Root Detection using Curvelet Transform
In this article a new method is introduced for distinguishing roots and background based on their digital curvelet transform in minirhizotron images. In the proposed method, the nonlinear mapping is applied on sub-band curvelet components followed by boundary detection using energy optimization concept. The curvelet transform has the excellent capability in detecting roots with different orient...
متن کاملCompliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography
Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be...
متن کاملCorrection of uneven illumination (vignetting) in digital microscopy images.
BACKGROUND Many digital microscopy images suffer from poor illumination at the peripheries (vignetting), often attributable to factors related to the light path between the camera and the microscope. A commonly used method for correcting this has been to use the illumination of an empty field as a correction filter (white shading correction). AIMS To develop an alternative shading correction ...
متن کاملارزیابی روشنایی در صنایع الکتریکی تهران
Background and Aim: Lack of quantitative and qualitative data on the current status and the possible adverse effect of poor illumination necessitate the evaluation of the illumination system in the industrial section. To perform quantitative and qualitative assessments of illumination conditions in factories located in the west of Tehran and to look at the adverse consequences of insufficient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Forensic science international
دوره 158 2-3 شماره
صفحات -
تاریخ انتشار 2006