RIBE Flux vs. Position Monitor

نویسنده

  • Thomas W. Hamilton
چکیده

Recent work at SNL has demonstrated unique capabilities to experimentally measure a variety of ion and neutral particle parameters inside surface features being etched, including ion energy, angular distributions, ion and neutral species measurements. This report details the construction of one recent laboratory tool designed to measure ion beam uniformity over the wafer surface in a reactive ion beam etch system, (RIBE). This information is critical to the development of accurate plasma processing computer models and simulation methods, and is essential for reducing the cost of introducing new processing technologies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Radiation-Induced Bystander Effect in QU-DB Cells after Acute and Fractionated Irradiation: An In Vitro Study

OBJECTIVE Radiation effects induced in non-irradiated cells are termed radiation-induced bystander effects (RIBE). The present study intends to examine the RIBE response of QU-DB bystander cells to first, second and third radiation fractions and compare their cumulative outcome with an equal, single acute dose. MATERIALS AND METHODS This experimental study irradiated three groups of target ce...

متن کامل

X-ray beam monitor made by thin-film CVD single-crystal diamond.

A novel beam position monitor, operated at zero bias voltage, based on high-quality chemical-vapor-deposition single-crystal Schottky diamond for use under intense synchrotron X-ray beams was fabricated and tested. The total thickness of the diamond thin-film beam monitor is about 60 µm. The diamond beam monitor was inserted in the B16 beamline of the Diamond Light Source synchrotron in Harwell...

متن کامل

The role of dose fractionation in the level of Radiation- Induced Bystander Effect in QU-DB Cells

Introduction: Radiation effects induced in non-irradiated cells are termed radiation- induced bystander effects (RIBE). The present study intends to examine the RIBE response of QU-DB bystander cells to first, second and third radiation fractions and compare their cumulative outcome with an equal, single acute dose.   Materials and Methods: This experimental ...

متن کامل

Position and flux stabilization of X-ray beams produced by double-crystal monochromators for EXAFS scans at the titanium K-edge.

The simultaneous and active feedback stabilization of X-ray beam position and monochromatic beam flux during EXAFS scans at the titanium K-edge as produced by a double-crystal monochromator beamline is reported. The feedback is generated using two independent feedback loops using separate beam flux and position measurements. The flux is stabilized using a fast extremum-searching algorithm that ...

متن کامل

Tests of the APS X-ray Transmitting Beam Position Monitors at ESRF

Two d i f f e r e m kynthetic diamond-based Xray transmitting beam position monitor (XBPM) prototypes have been studied with an undulator white beam at the European Synchrotron Radiation Facility (ESRF) ID-6 beamline. Of particular interest was the possibility of designing an integral window and filtedphoton beam position monitor for the Advanced Photon Source (APS) high heat flux insertion dev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000