Locking plate fixation for proximal humerus fractures.

نویسندگان

  • Scott D Pennington
  • Xavier A Duralde
چکیده

Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Osteosynthesis of Proximal Humeral End Fractures with Fixed-angle Plate and Locking Screws: Technique and Results

UNLABELLED Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. METHOD Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fra...

متن کامل

Tension wiring to increase stability of conventional plating for proximal humeral fractures: An alternative to a locking plate

Fixation of comminuted or osteoporotic fractures in the proximal humerus is a challenge for orthopedic surgeons. In the past two decades, locking plates have been used for proximal humeral fracture fixation. However, complications such as loss of reduction have been reported, and the implants are not always available in some regions. Therefore, we describe an alternative procedure involving fix...

متن کامل

Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri.

OBJECTIVE To compare the mechanical stability of a fixed-angle blade plate with that of a locking plate in a cadaveric proximal humerus fracture-fixation model subjected to cyclic loading. A secondary objective was to evaluate whether the use of synthetic humerus specimens would replicate significant differences found during cadaveric tests. DESIGN Mechanical evaluation of constructs in bendi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2012