A motion artifact generation and assessment system for the rapid testing of surface biopotential electrodes.

نویسندگان

  • Alper Cömert
  • Jari Hyttinen
چکیده

Dry electrodes can reduce cost while increasing the usability and comfort of wearable monitoring systems. They are, however, susceptible to motion artifacts. The present electrode testing methods lack reliability and do not separate the factors that affect the motion artifact. In this paper, we introduce a first generation motion artifact generation and assessment system that generates the speed, amplitude, and pattern-wise programmable movement of the electrode. The system simultaneously measures electrode-skin impedance, the motion artifact, and one channel of an electrocardiogram that contains the motion artifact and monitors the mounting force applied to the electrode. We demonstrate the system by comparing the applied movement and the measured signals for electrode movements up to 6 mm and movement frequencies from 0.4 Hz to 4 Hz. Results show that the impedance change and surface potential are visually clearly related to the applied motion, with average correlations of 0.89 and 0.64, respectively. The applied force, electrode location, and electrode structure all affect the motion artifact. The setup enables the motion of the electrode to be accurately controlled. The system can be used as a precursor to the testing of integrated systems because it enables thorough, repeatable, and robust motion artifact studies. The system allows a deeper insight into motion artifacts and the interplay of the various factors that affect them.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ambulatory Biopotential Measurement

AMBULATORY BIOPOTENTIAL MEASUREMENT by Lakshmi Chitra Penugonda Biopotential signals measure the electrical activity of different parts of the body. Conventional bedside monitors only provide information about the body under restricted conditions. Observation and documentation of biopotential signal during daily activities and the relation to patient symptoms may be important factors for clinic...

متن کامل

An active electrode for biopotential recording from small localized bio-sources

BACKGROUND Laser bio-stimulation is a well-established procedure in Medical Acupuncture. Nevertheless there is still a confusion as to whether it works or the effect is just placebo. Although a plethora of scientific papers published, showing positive clinical results, there is still a lack of objective scientific proofs about the bio-stimulation effect of lasers used in Acupuncture. The object...

متن کامل

Impedance spectroscopy of changes in skin-electrode impedance induced by motion

BACKGROUND The motion artifact is an ever-present challenge in the mobile monitoring of surface potentials. Skin-electrode impedance is investigated as an input parameter to detect the motion artifact and to reduce it using various methods. However, the impact of the used impedance measurement frequency on the relationship between measured impedance and the motion artifact and the relationship ...

متن کامل

Development of Hydrogel Membranes for Long Term Biopotential Monitoring Using Flexible Wet Electrodes

Ubiquitous monitoring of biopotentials can greatly enhance comfort, health and safety of patients dealing with chronic diseases. For home use, clinical grade adhesive electrodes are often cited as irritating and uncomfortable, leading to low usage compliance [1]. For long-term monitoring it is mandatory to have innocuous and disposable electrodes with constant impedance over long periods of tim...

متن کامل

Problems in Assessment of Novel Biopotential Front-End with Dry Electrode: A Brief Review

Developers of novel or improved front-end circuits for biopotential recordings using dry electrodes face the challenge of validating their design. Dry electrodes allow more user-friendly and pervasive patient-monitoring, but proof is required that new devices can perform biopotential recording with a quality at least comparable to existing medical devices. Aside from electrical safety requireme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2015