Heart Failure Effect of Cardiac Resynchronization Therapy on Reverse Remodeling and Relation to Outcome Multicenter Automatic Defibrillator Implantation Trial: Cardiac Resynchronization Therapy
نویسندگان
چکیده
Background—Cardiac resynchronization therapy (CRT) plus implantation of an implantable cardioverter defibrillator (ICD) reduced the risk of death or heart failure event in patients with mildly symptomatic heart failure, left ventricular dysfunction, and wide QRS complex compared with an ICD only. We assessed echocardiographic changes in patients enrolled in the MADIT-CRT trial (Multicenter Automatic Defibrillator Implantation Trial: Cardiac Resynchronization Therapy) to evaluate whether the improvement in outcomes with CRT plus an ICD was associated with favorable alterations in cardiac size and function. Methods and Results—A total of 1820 patients were randomly assigned to CRT plus an ICD or to an ICD only in a 3:2 ratio. Echocardiographic studies were obtained at baseline and 12 months later in 1372 patients. We compared changes in cardiac size and performance between treatment groups and assessed the relationship between these changes over the first year, as well as subsequent outcomes. Compared with the ICD-only group, the CRT-plus-ICD group had greater improvement in left ventricular end-diastolic volume index ( 26.2 versus 7.4 mL/m), left ventricular end-systolic volume index ( 28.7 versus 9.1 mL/m), left ventricular ejection fraction (11% versus 3%), left atrial volume index ( 11.9 versus 4.7 mL/m), and right ventricular fractional area change (8% versus 5%; P 0.001 for all). Improvement in end-diastolic volume at 1 year was predictive of subsequent death or heart failure, with adjustment for baseline covariates and treatment group; each 10% decrease in end-diastolic volume was associated with a 40% reduction in risk (P 0.001). Conclusions—CRT resulted in significant improvement in cardiac size and performance compared with an ICD-only strategy in patients with mildly symptomatic heart failure. Improvement in these measures accounted for the outcomes benefit. Clinical Trial Registration Information—URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271. (Circulation. 2010;122:985-992.)
منابع مشابه
Cardiac resynchronization therapy is more effective in women than in men: the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy) trial.
OBJECTIVES The purpose of this study was to investigate the factors related to sex-specific outcomes for death and heart failure events in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) trial. BACKGROUND In the MADIT-CRT trial, women seemed to achieve a better result from resynchronization therapy than men. METHODS All 1,820 pat...
متن کاملDouble mechanical prosthesis, correct international normalized ratio, and giant atrial mass.
Schalij MJ, Bax JJ. Optimal left ventricular lead position predicts reverse remodeling and survival after cardiac resynchronization therapy. J Am Coll Cardiol 2008;52: 1402–1409. 28. Yu Y, Kramer A, Spinelli J, Ding J, Hoersch W, Auricchio A. Biventricular mechanical asynchrony predicts hemodynamic effect of uniand biventricular pacing. Am J Physiol Heart Circ Physiol 2003;285:H2788–H2796. 29. ...
متن کاملEffect of cardiac resynchronization therapy on reverse remodeling and relation to outcome: multicenter automatic defibrillator implantation trial: cardiac resynchronization therapy.
BACKGROUND Cardiac resynchronization therapy (CRT) plus implantation of an implantable cardioverter defibrillator (ICD) reduced the risk of death or heart failure event in patients with mildly symptomatic heart failure, left ventricular dysfunction, and wide QRS complex compared with an ICD only. We assessed echocardiographic changes in patients enrolled in the MADIT-CRT trial (Multicenter Auto...
متن کاملHeart Failure Predictors of Response to Cardiac Resynchronization Therapy in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT)
Background—We hypothesized that combined assessment of factors that are associated with favorable reverse remodeling after cardiac resynchronization-defibrillator therapy (CRT-D) can be used to predict clinical response to the device. Methods and Results—The study population comprised 1761 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchroniza...
متن کاملCardiac resynchronization therapy reduces left atrial volume and the risk of atrial tachyarrhythmias in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy).
OBJECTIVES We hypothesized that reductions in left atrial volume (LAV) with a cardiac resynchronization therapy-defibrillator (CRT-D) would translate into a subsequent reduction in the risk of atrial tachyarrhythmias (AT). BACKGROUND There is limited information regarding the effect of CRT-D on the risk of AT. METHODS Percent reduction in LAV at 1 year following CRT-D implantation (pre-spec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -