Methods of reducing non-specific adsorption in microfluidic biosensors

نویسندگان

  • Seokheun Choi
  • Junseok Chae
چکیده

Non-specific adsorption (NSA) of biomolecules is a persistent challenge in microfluidic biosensors. Microfluidic biosensors often have immobilized bioreceptors such as antibodies, enzymes, DNAs, etc, via linker molecules such as SAMs (self-assembled monolayers) to enhance immobilization. However, the linker molecules are very susceptible to NSA, causing false responses and decreasing sensitivity. In this paper, we present design methods to reduce the NSA of alkanethiol SAMs, which are popular linker molecules on microfluidic biosensors. Three design parameters were studied for two different chain-length SAMs (n = 2 and 10): (i) SAM incubation time, (ii) surface roughness [0.8 nm and 4.4 nm RMS (root mean square)] and (iii) gold crystal re-growth along (1 1 1) the target orientation. NSA was monitored by surface plasmon resonance (SPR). The results suggest that increased SAM incubation time reduces NSA, and that short-chain SAMs respond more favorably than the long-chain SAMs. Both SAMs were shown to be sensitive to surface roughness, and long-chain SAMs reduced NSA by 75%. Gold crystal re-growth along (1 1 1) the target orientation profoundly reduced NSA on the short-chain SAM. On a gold surface where surface roughness was 0.8 nm and there was strong directional alignment along the (1 1 1) gold crystal, final concentrations of nonspecifically bound proteins were 0.05 ng mm−2 (fibrinogen) and 0.075 ng mm−2 (lysozyme)—significantly lower than other known methods. The results show that optimizing three parameters (SAM incubation time, gold surface roughness and gold crystal orientation) improved SAM sensitivity for fibrinogen–anti-fibrinogen conjugates by a factor of 5 in 2.94 pM, suggesting that the methods are effective for reducing NSA in microfluidic biosensors. (Some figures in this article are in colour only in the electronic version)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PEG Functionalization of Whispering Gallery Mode Optical Microresonator Biosensors to Minimize Non-Specific Adsorption during Targeted, Label-Free Sensing

Whispering Gallery Mode (WGM) optical microresonator biosensors are a powerful tool for targeted detection of analytes at extremely low concentrations. However, in complex environments, non-specific adsorption can significantly reduce their signal to noise ratio, limiting their accuracy. To overcome this, poly(ethylene glycol) (PEG) can be employed in conjunction with appropriate recognition el...

متن کامل

Transient convection, diffusion, and adsorption in surface-based biosensors.

This paper presents a theoretical and computational investigation of convection, diffusion, and adsorption in surface-based biosensors. In particular, we study the transport dynamics in a model geometry of a surface plasmon resonance (SPR) sensor. The work, however, is equally relevant for other microfluidic surface-based biosensors, operating under flow conditions. A widely adopted approximate...

متن کامل

Adsorption of proline amino acid on the surface of fullerene (C20) and boron nitride cage (B12N12): A comprehensive DFT study

In this study, the performance of fullerene (C20) and boron nitride cage (B12N12) as a sensing material for detection of proline was evaluated by density functional theory. For this purpose, the structures of proline, C20, B12N12 and the derived products from the proline adsorption on the surface of nanostructures were optimized geometrically. Then, IR and Frontier molecular orbital calculation...

متن کامل

Biosensors based on nanomechanical systems.

The advances in micro- and nanofabrication technologies enable the preparation of increasingly smaller mechanical transducers capable of detecting the forces, motion, mechanical properties and masses that emerge in biomolecular interactions and fundamental biological processes. Thus, biosensors based on nanomechanical systems have gained considerable relevance in the last decade. This review pr...

متن کامل

Combining an optical resonance biosensor with enzyme activity kinetics to understand protein adsorption and denaturation.

Understanding protein adsorption and resultant conformation changes on modified and unmodified silicon dioxide surfaces is a subject of keen interest in biosensors, microfluidic systems and for medical diagnostics. However, it has been proven difficult to investigate the kinetics of the adsorption process on these surfaces as well as understand the topic of the denaturation of proteins and its ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010