The monopole-source solution was used to calculate the three-dimensional complex acoustic pressure field for one-dimensional focused rectangular apertures in a medium having homogeneous acoustic and thermal properties. For each of six frequencies (1, 3, 5, 7, 9 and 12 MHz) and three focuses (f/1, f/2 and f/4), 33 rectangular aperture cases were investigated, for a total of 594 cases. For these focused field geometries, the three-dimensional temperature distribution was calculated using the bioheat transfer equation in homogeneous perfused media (attenuation = absorption: 0.3 dB/cm-MHz; perfusion length: 1.0 cm). For each of the 594 cases, the acoustic field was normalized to the derated spatial-peak temporal-average intensity (ISPTA.3) of 720 mW/cm2, the maximum value condition allowed based on the U.S. Food and Drug Administration (FDA) regulatory limit for most diagnostic ultrasound (US) equipment. Using the normalized acoustic field, the axial temperature increase profiles and the maximum temperature increases (DeltaTmax) were determined for each case. Also, from the normalized acoustic field, the unscanned-mode soft-tissue thermal index (TIS) for the rectangular sources was determined according to the procedures of the Standard for Real-Time Display of Thermal and Mechanical Indices on Diagnostic Ultrasound Equipment, commonly called the output display standard, ODS. The DeltaTmax:TIS ratio of the 594 cases yielded a mean value of 0.22, a median value of 0.16, a maximum value of 1.04 and a minimum value of 0.039. For all but one of the cases, TIS was greater than DeltaTmax. Also, two new unscanned-mode soft-tissue thermal indices (denoted TIS(new1) and TIS(new2)) were proposed. For new model 1, the DeltaTmax: TIS(new1) ratio yielded a mean value of 1.02, a median value of 1.01, a maximum value of 1.83 and a minimum value of 0.44. For new model 2, the DeltaTmax: TIS(new2) ratio yielded a mean value of 1.04, a median value of 0.99, a maximum value of 2.31 and a minimum value of 0.34. Further, both new models fit more closely to DeltaTmax than does the ODS-determined TIS and have the potential of being easier for manufacturers to implement because only the source power and frequency need to be measured.
منابع مشابه
Comparison of Soft Tissue Thermal Changes Induced by Three Types of Diode Lasers at 810, 940, and 980nm Wavelengths
Background and Aim: Diode laser is a great choice for soft tissue surgery. The diode laser is partially absorbed by hard dental tissues, making it safe for soft tissue surgery. This study aimed to compare the tissue thermal changes induced by three types of diode lasers at 810, 940, and 980nm wavelengths. Materials and Methods: In this in-vitro experimental study, using a diode laser device (c...
متن کاملNew distance and similarity measures for hesitant fuzzy soft sets
The hesitant fuzzy soft set (HFSS), as a combination of hesitant fuzzy and soft sets, is regarded as a useful tool for dealing with the uncertainty and ambiguity of real-world problems. In HFSSs, each element is defined in terms of several parameters with arbitrary membership degrees. In addition, distance and similarity measures are considered as the important tools in different areas such as ...
متن کاملAn adaptive estimation method to predict thermal comfort indices man using car classification neural deep belief
Human thermal comfort and discomfort of many experimental and theoretical indices are calculated using the input data the indicator of climatic elements are such as wind speed, temperature, humidity, solar radiation, etc. The daily data of temperature، wind speed، relative humidity، and cloudiness between the years 1382-1392 were used. In the First step، Tmrt parameter was calculated in the Ray...
متن کاملClinical evaluation of soft tissue surrounding prosthesis supported by implants
Clinical evaluation of soft tissue surrounding prosthesis supported by implants Dr. A. Fazel* - Dr. M. Rismanchian** *- Associate Professor of Prosthodontics Dept. - Faculty of Dentistry - Tehran University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry - Isfahan University of Medical Sciences. Background and Aim: Nowadays, reconstruction and replace...
متن کاملاندازه گیری تمرکز موضوعی و پژوهشگران متمرکز بر آن
Introduction: In the universities and academic institutes, most of the research activities are performed in departments and research centers, which are evaluated by measurement of indices such as number of academics and students, number of publications and patents, citation analysis, journals in which their reports have been published, the amount of grants etc. Methods: Academic department is c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ultrasound in medicine & biology
دوره 30 7 شماره
صفحات -
تاریخ انتشار 2004