Evaluation of two methods in controlling dental treatment water contamination.

نویسندگان

  • Ritu Bansal
  • Raghunath Puttaiah
  • Robert Harris
  • Anil Reddy
چکیده

UNLABELLED Dental unit water systems are contaminated with biofilms that amplify bacterial counts in dental treatment water in excess of a million colony forming units per milliliter (cfu/ml). The Centers for Disease Control and Prevention and the American Dental Association have agreed that the maximum allowable contamination of dental treatment water not exceed 500 cfu/ml. This study was conducted to evaluate two protocols in controlling contamination of dental unit water systems and dental treatment water. Both methods used an antimicrobial self-dissolving chlorine dioxide (ClO₂) tablet at a high concentration (50 ppm) to shock the dental unit water system biofilms initially followed by periodic exposure. To treat dental treatment source water for patient care, 3 parts per million (ppm) ClO₂ in municipal/tap water was compared to use of a citrus botanical extract dissolved in municipal water. Heterotrophic microbial counts of effluent water and laser scanning confocal microscopy were performed to evaluate effects of the two treatments. Results from this study indicated that both treatments were effective in controlling biofilm contamination and reducing heterotrophic plate counts <500 cfu/ml. A comprehensive study addressing compatibility of 50 ppm ClO₂ on the metals and nonmetal components of the dental water system and effects of low-grade chemicals used on composite bonding to dentin and enamel is warranted before translation from efficacy studies to common clinical use. CLINICAL SIGNIFICANCE This study provides evidence-based information of using two methods of controlling dental treatment water contamination. The study was conducted in a clinical practice setting in an active dental clinic and the results are meaningful to a clinician who is interested in providing safe dental treatment water for patient care. KEYWORDS Dental waterline biofilms, Dental treatment water contamination control, Chlorine dioxide, Emulsifiers, Heterotrophic plate counts, Laser scanning confocal microscopy. How to cite this article: Bansal R, Puttaiah R, Harris R, Reddy A. Evaluation of Two Methods in Controlling Dental Treatment Water Contamination. J Contemp Dent Pract 2011;12(2):73-83. Source of support: Nil Conflict of interest: None declared.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Bacterial Contamination in Dental Unit Water Lines in Zahedan in 2016-2017

Background & Aim: Due to a constant contact of dentists and patients with water and aerosols generated from the dental units, the quality of dental unit waters is very important. This study aimed to evaluate bacterial contamination of dental unit water lines in Zahedan in 2016-2017. Methods: In this descriptive analytical study, 2304 water samples from four parts of unit including cup filler, ...

متن کامل

Frequency evaluation of Pseudomonas SPP contamination in the dental unit water line system at Mashhad dental school

Background and aim: One of the well-known bacteria in dental unit water contamination is Pseudomonas aueroginosa. The aim of the present study was to evaluate the amount of Pseudomonas aeruginosa species infection in the dental unit water samples of Dental Faculty of Mashhad University of Medical Sciences. Material and methods: Water samples collected randomly from the turbines of 10% of the ac...

متن کامل

Evaluation of Bacterial Contamination in Clinical Environment of Sari Dental School in 2018

Background and Aim: Bacterial contamination of clinical surfaces of dental units that have been touched or been exposed to patients’ blood or saliva can be a reservoir for infections, leading to cross-contamination. This study aimed to evaluate bacterial contamination in the clinical environment of Sari Dental School in 2018. Materials and Methods: In this cross-sectional (descriptive-analytic...

متن کامل

Multiple approaches to control dental unit water line biofilm contamination

Biofilms form rapidly on dental unit waterlines. The specific design of dental units favors bacteria to colonize surfaces and to form biofilm in water supply tubes, including dental unit water line (DUWL). The majority of the organisms in the biofilm are harmless environmental species, but some dental units may harbour opportunistic respiratory pathogens. Microbiological control of dental unit ...

متن کامل

Evaluation of Bacterial Contamination Level of Waterlines in Dental Units in Dentistry School of Qom University of Medical Sciences in 2018

Background and Objectives: According to hazardous infection possibility in patients with a weakened immune system, old adults, and children, microbial contamination in the waterlines of dental units has become a recent concern. The aim of the present study was to evaluate the microbial contamination in dental unit waterlines in the School of Dentistry, Qom University of Medical Sciences, Qom, I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2011