Left ventricular twist is load-dependent as shown in a large animal model with controlled cardiac load
نویسندگان
چکیده
BACKGROUND Left ventricular rotation and twist can be assessed noninvasively by speckle tracking echocardiography. We sought to characterize the effects of acute load change and change in inotropic state on rotation parameters as a measure of left ventricular (LV) contractility. METHODS Seven anesthetised juvenile pigs were studied, using direct measurement of left ventricular pressure and volume and simultaneous transthoracic echocardiography. Transient inflation of an inferior vena cava balloon (IVCB) catheter produced controlled load reduction. First and last beats in the sequence of eight were analysed with speckle tracking (STE) during the load alteration and analysed for change in rotation/twist during controlled load alteration at same contractile status. Two pharmacological inotropic interventions were also included to examine the same hypothesis in additionally conditions of increased and decreased myocardial contractility in each animal. Paired comparisons were made for different load states using the Wilcoxon's Signed Rank test. RESULTS The inferior vena cava balloon occlusion (IVCBO) load change compared for first to last beat resulted in LV twist increase (11.67° ±2.65° vs. 16.17° ±3.56° respectively, p < 0.004) during the load alteration and under adrenaline stimulation LV twist increase 12.56° ±5.1° vs. 16.57° ±4.6° (p < 0.013), and though increased, didn't reach significance in negative inotropic condition. Untwisting rate increased significantly at baseline from -41.7°/s ±41.6°/s vs.-122.6°/s ±55.8°/s (P < 0.039) and under adrenaline stimulation untwisting rate increased (-55.3°/s ±3.8°/s vs.-111.4°/s ±24.0°/s (p < 0.05), but did not systematically changed in negative inotropic condition. CONCLUSIONS Peak systolic LV twist and peak early diastolic untwisting rate are load dependent. Differences in LV load should be included in the interpretation when serial measures of twist are compared.
منابع مشابه
A New Load-Flow Method in Distribution Networks based on an Approximation Voltage-Dependent Load model in Extensive Presence of Distributed Generation Sources
Power-flow (PF) solution is a basic and powerful tool in power system analysis. Distribution networks (DNs), compared to transmission systems, have many fundamental distinctions that cause the conventional PF to be ineffective on these networks. This paper presents a new fast and efficient PF method which provides all different models of Distributed Generations (DGs) and their operational modes...
متن کاملLeft ventricular strain and peak systolic velocity: responses to controlled changes in load and contractility, explored in a porcine model
BACKGROUND Tissue velocity echocardiography is increasingly used to evaluate global and regional cardiac function. Previous studies have suggested that the quantitative measurements obtained during ejection are reliable indices of contractility, though their load-sensitivity has been studied in different settings, but still remains a matter of controversy. We sought to characterize the effects ...
متن کاملبهبود پایداری شبکه قدرت با روش جدید حذف بار ترکیبی
Power system blackouts have become a serious problem for electric utilities especially in recent years. Different forms of system instability have emerged in recent blackouts, such as voltage instability and frequency instability. To counteract each form of system instability, special algorithms have been designed in the protection system, e.g. Under Frequency Load Shedding (UFLS) and Under Vol...
متن کاملLeft ventricular function ' s relation to load , experimental studies in a porcine model . Roman
Left ventricular function's relation to load, experimental studies in a porcine model. Abstract 4 ABSTRACT Background: Loading conditions are recognized to influence ventricular function according to the Starling relationship for length/stretch and force. Many modern echocardio-graphic parameters which have been announced as describing ventricular function and contractile status, may be confoun...
متن کاملDefining left ventricular apex-to-base twist mechanics computed from high-resolution 3D echocardiography: validation against sonomicrometry.
OBJECTIVES To compute left ventricular (LV) twist from 3-dimensional (3D) echocardiography. BACKGROUND LV twist is a sensitive index of cardiac performance. Conventional 2-dimensional based methods of computing LV twist are cumbersome and subject to errors. METHODS We studied 10 adult open-chest pigs. The pre-load to the heart was altered by temporary controlled occlusion of the inferior ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2012