Clinical experience of a vacuum-assisted nonroller extra-corporeal circulation system.

نویسندگان

  • M Hiroura
  • T Furusawa
  • M Amino
  • T Moriya
  • H Goto
  • Y Fukaya
  • J Amano
چکیده

We designed a nonroller extra-corporeal circulation system (NRECC) to minimize space requirements and to improve the safety and ease of cardiopulmonary bypass. The NRECC includes a circuit, a centrifugal pump, and a vacuum regulator. The vacuum regulator has five channels, each of which can control negative pressure independently. Negative pressure is applied to suctions, a vent, and a venous reservoir. Auto Vent-SV and one-way valves were placed between the suctions/vent and the reservoir. The total space required for the NRECC with a heat exchanger was 0.49 m2, which is much smaller than that of our current roller pump system. The maximum volume through the suction/vent was 2.5 L/min at -100 mmHg measured in a simulated system. We used the NRECC for six CABG cases and compared results with those of five CABG cases managed by traditional roller pump extra-corporeal circulation (RECC). The two systems were compared in terms of set-up time and stability/accuracy of the suction/vent. The set-up time of the NRECC (5.3 +/- 1.9 min) was significantly shorter than that of RECC (29 +/- 3.4 min) (p < .01). Stable and accurate blood flow were achieved with the NRECC operating between -15 mmHg and -25 mmHg. In conclusion, NRECC can run a bypass easily and safely and has the benefit of reducing space requirements and shortening set-up time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical outcomes of pulmonary valve replacement surgery in pediatrics: a single-center experience long-term study

Introduction: Heart valve disease in pediatricsis an increasing global concern, especially in developing countries. This study aims to determine the clinical outcomes of pulmonary valve replacement (PVR) surgery in pediatrics. Methods: The authors retrospectively identified all pediatrics undergoing PVR surgery at Imam Reza hospital (Mashhad, Iran) between 2000 and 2020. Their medical records...

متن کامل

A model of venous return while utilizing vacuum assist during cardiopulmonary bypass.

In order for vacuum-assisted venous return (VAVR) to be used safely and efficiently during cardiopulmonary bypass (CPB), a full understanding of venous return is necessary. The focus of this work was to use the concepts of energy conservation and viscous energy dissipation in the development of a theoretical model of venous return utilizing vacuum assist. The effectiveness and accuracy of this ...

متن کامل

Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass.

When conventional gravity siphon venous drainage cannot achieve satisfactory venous drainage during minimally invasive cardiac and neonatal surgeries, assisted venous drainage techniques are needed to ensure adequate flow. One assisted venous drainage technique, vacuum-assisted venous drainage (VAVD), the aid of a vacuum in the venous reservoir, is now widely used to augment venous drainage dur...

متن کامل

Experimental use of an ultra-low prime neonatal cardiopulmonary bypass circuit utilizing vacuum-assisted venous drainage.

In adult cardiopulmonary bypass surgery, vacuum assisted venous drainage has become a popular technique to augment venous return to the bypass circuit. The application of this technique in neonatal cardiopulmonary bypass surgery could be beneficial to the further miniaturization of neonatal circuitry by coupling radical respositioning of the oxygenator and pump console with decreasing line leng...

متن کامل

Can vacuum assisted venous drainage be achieved using a roller pump in an emergency? A pilot study using neonatal circuitry.

There has been much advancement in perfusion technology over its 50 years of progression. One of these techniques is vacuum-assisted venous drainage (VAVD). Many perfusionists augment venous drainage using VAVD, typically from a wall vacuum source. This study explores alternates to providing VAVD if the wall vacuum fails. In two porcine laboratories, approximately 36 in. of 3/16-in. tubing was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 32 3  شماره 

صفحات  -

تاریخ انتشار 2000