A Reconfigurable Electrode Array for Use in Rotational Electrical Impedance Myography

نویسندگان

  • Michael Scharfstein
  • Joel L. Dawson
  • Arthur C. Smith
چکیده

This thesis describes the design of a novel handheld electrode probe and measurement system for use in rotational electrical impedance myography (EIM), which is a method for diagnosing neuromuscular disease. The probe can be controlled from a PC via USB and uses an array of small electrode cells that can be connected together into larger electrodes with the help of crosspoint switches. A measurement system capable of fast multifrequency impedance measurement has also been developed. The two systems have performed well, with measurements being very close to those achieved by more traditional electrical impedance myography methods. Thesis Supervisor: Joel L. Dawson Title: Assistant Professor

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A portable system for the assessment of neuromuscular diseases with electrical impedance myography.

PRIMARY OBJECTIVE To create a system for the acquisition of multi-angle, multifrequency muscle impedance data. RESEARCH DESIGN Device development and preliminary testing. METHODS AND PROCEDURES The system presented here employs an interrogating signal composed of multiple tones with frequencies between 10 kHz and 300 kHz. The use of a composite signal makes possible measurement of impedance...

متن کامل

The effect of subcutaneous fat on electrical impedance myography when using a handheld electrode array: the case for measuring reactance.

OBJECTIVE Recent developments in electrical impedance myography (EIM) have led to the use of handheld electrode arrays (HEAs) for data acquisition. Although preferable for several reasons, this approach tends to be more affected by subcutaneous fat (SF) than the original approach in which the impedance-measuring electrodes are widely spaced. In this study, we seek to identify the EIM parameter ...

متن کامل

The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses

This study investigates the impact of the subcutaneous fat layer (SFL) thickness on localized electrical impedance myography (EIM), as well as the effects of different current electrodes, varying in distance and direction, on EIM output. Twenty-three healthy subjects underwent localized multi-frequency EIM on their biceps brachii muscles with a hand-held electrode array. The EIM measurements we...

متن کامل

Flexible Electrode Array for Retinal Stimulation

In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...

متن کامل

Guidelines to electrode positioning for human and animal electrical impedance myography research

The positioning of electrodes in electrical impedance myography (EIM) is critical for accurately assessing disease progression and effectiveness of treatment. In human and animal trials for neuromuscular disorders, inconsistent electrode positioning adds errors to the muscle impedance. Despite its importance, how the reproducibility of resistance and reactance, the two parameters that define EI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007