Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography.
نویسندگان
چکیده
AIMS Current improvements in spatial, temporal, and contrast resolution of multislice computed tomography (CT) could be useful in the assessment of valvular diseases. We evaluated the diagnostic accuracy of multislice CT for the identification and quantification of aortic valvular stenosis (AS), compared with echography. METHODS AND RESULTS Consecutive patients, referred for coronary CT, were evaluated for AS, by the use of standard electrocardiography-gated 16-slice CT protocol. Multiplanar reformat was applied to systolic phases of the cardiac cycle, with projection on thick slices for measuring the aortic valvular area (AVA). CT results were compared with echocardiographic-based measurement of the AVA. Among 107 enrolled patients, CT analysis of the AVA was feasible in 103. Among the 30 patients with AS, Bland-Altman analysis showed good agreement between the two methods [mean difference -7 mm(2) (-40-25 mm(2))]. CONCLUSION CT analysis of aortic valve is feasible in most cases and allows for reliable diagnosis and quantification of AS.
منابع مشابه
Imaging of Cardiac Valves by Computed Tomography
This paper describes "how to" examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, "how to" perform and optimize a multislice CT scan and "how to" interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease...
متن کامل[Coronary angiography by 16-slice computed tomography prior to valvular surgery].
INTRODUCTION AND OBJECTIVES Multislice computed tomography is an excellent technique for the detection of significant coronary artery lesions. Our purpose was to assess whether computed tomography could replace routine invasive coronariography before valvular surgery. METHODS We studied 106 consecutive patients (mean age: 67 [10]): 76% aortic valvular disease (62% stenosis, 14% regurgitation)...
متن کاملCARDIOVASCULAR MEDICINE Three dimensional volume quantification of aortic valve calcification using multislice computed tomography
Objective: To assess a new multislice computed tomography (CT) technique for three dimensional quantification of aortic valve calcification volume (3D AVCV) and to study the relation between stenosis and calcification of the aortic valve. Methods: 50 patients with echocardiographic calcification of the aortic valve underwent two separate ECG triggered multislice CT for quantification of 3D AVCV...
متن کاملThree dimensional volume quantification of aortic valve calcification using multislice computed tomography.
OBJECTIVE To assess a new multislice computed tomography (CT) technique for three dimensional quantification of aortic valve calcification volume (3D AVCV) and to study the relation between stenosis and calcification of the aortic valve. METHODS 50 patients with echocardiographic calcification of the aortic valve underwent two separate ECG triggered multislice CT for quantification of 3D AVCV...
متن کاملPatient selection for transcatheter aortic valve replacement: A combined clinical and multimodality imaging approach
Transcatheter aortic valve replacement (TAVR) has been validated as a new therapy for patients affected by severe symptomatic aortic stenosis who are not eligible for surgical intervention because of major contraindication or high operative risk. Patient selection for TAVR should be based not only on accurate assessment of aortic stenosis morphology, but also on several clinical and functional ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European heart journal
دوره 27 24 شماره
صفحات -
تاریخ انتشار 2006