Review and evaluation of the potential impact of age- and gender-specific pharmacokinetic differences on tissue dosimetry.
نویسندگان
چکیده
In standard risk assessment methods for carcinogenic or noncarcinogenic chemicals, quantitative methods for evaluating interindividual variability are not explicitly considered. These differences are currently considered by the use of statistical confidence limits or default uncertainty factors. This investigation consisted of multiple tasks aimed at making quantitative predictions of interindividual differences in susceptibility by using physiologically based pharmacokinetic (PBPK) models. Initially, a systematic, comprehensive review of the literature was conducted to identify any quantitative information related to gender- or age-specific physiological and biochemical factors that could influence susceptibility to chemical exposure. These data were then organized from a pharmacokinetic perspective by process and by chemical class to identify key factors likely to have a significant impact on susceptibility as it relates to internal target tissue dose. Overall, a large number of age- and gender-specific quantitative differences in pharmacokinetic parameters were identified. The majority of these differences were identified between neonates/children and adults, with fewer differences identified between young adults and the elderly. The next phase of this work consists of using PBPK models to develop examples of approaches through the development of case studies. The goal of the case studies is to continue to develop a methodology that incorporates PBPK modeling to assess the likelihood that a chemical or class of chemicals may present an age- or gender-specific risk. The case studies should also demonstrate practical methods for quantitatively incorporating information on age- and gender-specific pharmacokinetic differences in risk assessments for chemicals.
منابع مشابه
Growth and Functional Development in 6 to 10 Years Old Soccer Players: Constraints and Possibilities
Sport and more specifically football is an important asset in youth lives. It is widely considered that biological maturity influences physical performance. Relationships between body size and performance are partly confounded by age. In fact, age is positively associated to strength and motor performance, even when height and weight are controlled. Studies on young footballer have been start...
متن کاملDental tissue as a TLD dosimeter
Background: Thermoluminescence dosimetry is one of the dosimetry procedures used widely as routine and personal dosimeters. In order to extend this kind of dosimeters, dental tissue has been examined and was found promising as a TLD dosimeter. Materials and Methods : In this study, 70 health teeth were collected. The only criterion, which was considered for selection of the teeth, was the healt...
متن کاملDevelopment of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کاملA study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy
Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...
متن کاملAn investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy
Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Toxicological sciences : an official journal of the Society of Toxicology
دوره 79 2 شماره
صفحات -
تاریخ انتشار 2002