In vitro evaluation of force degradation of elastomeric chains used in orthodontics.

نویسندگان

  • André Weissheimer
  • Arno Locks
  • Luciane Macedo de Menezes
  • Adriano Ferreti Borgatto
  • Carla D'Agostini Derech
چکیده

OBJECTIVE To analyze the in vitro force degradation of four different brands of elastomeric chains: American Orthodontics, Morelli, Ormco and TP Orthodontics. METHODS The sample consisted of 80 gray elastomeric chains that were divided into four groups according to their respective manufacturers. Chain stretching was standardized at 21 mm with initial force release ranging from 300 g to 370 g. The samples were kept in artificial saliva at a constant temperature of 37°C and the degradation force was recorded at the following time intervals: initial, 1, 3, 5, 7 and 9 hours, and 1, 7, 14, 21, 28, and 35 days. RESULTS There was a statistically significant difference between the groups regarding the force degradation, mainly within the first day, as a force loss of 50-55% was observed during that time in relation to the initial force. The force delivered at 35 days ranged from 122 g to 148 g. CONCLUSIONS All groups showed force degradation over time, regardless of their trademarks, a force loss of 59-69% was observed in the first hour compared to baseline. However, because the variation in force degradation depends on the trademark, studies such as the present one are important for guiding the clinical use of these materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the elastomeric behavior and force degradation pattern between different orthodontic elastomeric chains

Background and Aims: Elastomeric chains are known as a current device with the purpose of dental movement in orthodontic treatments. The aim of this study was to compare the elastomeric behavior and force degradation rate between different elastomeric chains existing in Iran in different time durations. Materials and Methods: 11 different elastomeric chains used in this study were: Class One, ...

متن کامل

Force-Degradation Pattern of Six Different Orthodontic Elastomeric Chains

OBJECTIVE An ideal orthodontic force system should exert continuous light force. Thus, many efforts have been made to improve the memory characteristics of elastomeric chains. The aim of this study was to compare elastomeric chains (ECs) claimed by their manufacturers to offer high memory with traditional ones according to their force-extension diagrams. MATERIALS AND METHODS In this in-vitro...

متن کامل

In vitro evaluation of force delivered by elastomeric chains

Objective: To evaluate and compare, in vitro, the decrease in the forces delivered in three groups of elastomeric chains, produced by the same manufacturer, according to the distance between links (short, medium, long). Methods: The segments of elastomeric chains were stretched and kept activated during the trial using a device developed especially for this purpose, which also allowed force rea...

متن کامل

Application of Elastomeric Chains in Orthodontics: Past, Present and Future

Context: One of the most important aims in orthodontic treatment is to apply a light continuous force to achieve maximum effective tooth movement with minimal side effects (optimal tooth movement). It is obvious that elastomeric chains are the most popular method of space closure, but they undergo force decay during time. Force decay behavior of elastomeric chains is influenced by various facto...

متن کامل

An investigation into UV light exposure as an experimental model for artificial aging on tensile strength and force delivery of elastomeric chain.

This study investigated the effect of ultraviolet type A light (UVA) exposure on the tensile properties of elastomeric chain. UVA light exposure was used as model for artificial aging, simulating prolonged storage of elastomeric chain. Tensile strength (n = 60) was measured after exposing Ormco, Forestadent and 3M chains to UVA light for 0, 2, 3, and 4 weeks. Force decay was measured (n = 60) u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dental press journal of orthodontics

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 2013