Predictability of Tunnel Depth for Intrastromal Corneal Ring Segments Implantation Between Manual and Femtosecond Laser Techniques.

نویسندگان

  • Tiago Monteiro
  • José F Alfonso
  • Nuno Franqueira
  • Fernando Faria-Correia
  • Renato Ambrósio
  • David Madrid-Costa
چکیده

PURPOSE To compare the predictability of intrastromal tunnel depth creation for intrastromal corneal ring segments (ICRS) implantation between manual dissection and femtosecond laser using a high-resolution anterior segment optical coherence tomography (AS-OCT). METHODS This multicenter study included patients with keratoconus who had Ferrara-type ICRS implantation at Hospital de Braga using manual dissection and at the Fernandez-Vega Ophthalmological Institute using the femtosecond laser technique. The intended depth of implantation was compared to the achieved postoperative ICRS depth of each case, measured using a swept-source AS-OCT (CASIA SS-1000; Tomey Corporation, Nagoya, Japan) at three points (proximal, central, and distal end of the implant). RESULTS The study included 105 eyes in the manual group and 53 eyes in the femtosecond laser group. The differences of the intended versus the achieved depth were statistically higher in the manual group for all positions measured (Wilcoxon ranked-sum, P < .001). In the manual group, there were significant differences between the mean values of intended and achieved depth after surgery for the three locations measured (Wilcoxon signed-rank, P < .05), whereas there were no significant differences in the femtosecond laser group. In the manual group, the proximal part of the stromal tunnel was significantly shallower (-40.87 ± 69.03 μm) than the central (-25.54 ± 71.00 μm) and distal (-26.52 ± 73.22 μm) parts (Friedman test, P < .05). CONCLUSIONS ICRS implantation assisted by a femtosecond laser provides a more precise procedure considering dissection depth when compared with the manual dissection technique. Such an advantage may provide more predictable clinical results and safer procedures with the femtosecond laser. [J Refract Surg. 2018;34(3):188-194.].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction.

PURPOSE To report the outcomes after the implantation of intrastromal corneal ring segments (KERARING) aided by femtosecond laser for the correction of keratoconus. DESIGN Prospective consecutive interventional study. PARTICIPANTS Twenty-one eyes of 16 consecutive keratoconic patients with mean age 32+/-10.2 years. Forty-five percent were keratoconus grade I, 20% grade II, 15% grade III, an...

متن کامل

Intrastromal corneal ring segment implantation with the femtosecond laser in a post-keratoplasty patient with recurrent keratoconus.

A 50-year-old woman had implantation of intrastromal corneal ring segments for recurrent keratoconus 15 years after penetrating keratoplasty. Two segments (0.15 mm and 0.25 mm) were inserted without any intraoperative or postoperative complications, using the femtosecond laser to create the tunnels (superior and inferior). Ten months after the procedure, the uncorrected visual acuity was 20/100...

متن کامل

Advances in femtosecond laser technology

Femtosecond laser technology has become widely adopted by ophthalmic surgeons. The purpose of this study is to discuss applications and advantages of femtosecond lasers over traditional manual techniques, and related unique complications in cataract surgery and corneal refractive surgical procedures, including: LASIK flap creation, intracorneal ring segment implantation, presbyopic treatments, ...

متن کامل

Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up

PURPOSE We attempted to evaluate the efficacy of femtosecond laser-assisted intrastromal corneal ring segment implantation in patients with keratoconus (KC). PATIENTS AND METHODS A retrospective interventional consecutive clinical study was conducted on patients with KC who were treated with femtosecond laser Keraring implantation. All procedures were performed at Ebsar Eye Center in the peri...

متن کامل

Complications of intrastromal corneal ring segment implantation using a femtosecond laser for channel creation: a survey of 850 eyes with keratoconus.

PURPOSE To report complications after the implantation of intrastromal corneal ring segments (Keraring; Mediphacos, Belo Horizonte, Brazil) in keratoconic eyes using a femtosecond laser (IntraLase; Advanced Medical Optics, Santa Ana, California, USA) for channel creation. METHODS Retrospective chart review of 531 patients (850 eyes) who underwent Keraring insertion using a femtosecond laser f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 2018