Overview of the Spear3 Vacuum System*
نویسندگان
چکیده
The conceptual design of the vacuum system for the upgrade project of SPEAR3 is reviewed. The majority of the vacuum system components, except for insertion devices, will be replaced with components capable of 500 mA operation at 3 GeV. General requirements and overall layout of the vacuum system are discussed. Diagnostic chambers and speciality components are briefly discussed.
منابع مشابه
Observation of Beam Ion Instability in Spear3*
Weak vertical coupled bunch instability with oscillation amplitude at μm level has been observed in SPEAR3. The instability becomes stronger when there is a vacuum pressure rise by partially turning off vacuum pumps and it becomes weaker when the vertical beam emittance is increased by turning off the skew quadrupole magnets. These confirmed that the instability was driven by ions in the vacuum...
متن کاملSpear3 Booster Rf System Upgrade: Performance Requirements and Evaluation of Resources*
The SPEAR2 accelerator system originally had 3 RF stations (2 for storage ring, 1 Booster) operating at 358.5 MHz. SPEAR3 now operates at 476.3 MHz with the PEPII type RF system, while the Booster RF frequency remains unchanged. For top-off operation, the Booster injects single 3.0 GeV electron bunches into SPEAR3 at 10 Hz every 5 minutes to replenish lost charge. Due to the frequency mismatch ...
متن کاملFast Global Orbit Feedback System in Spear3*
The new fast orbit feedback system (FOFB) is being commissioned at the SPEAR3 light source. The system has a 4kHz sampling rate and 100Hz bandwidth. The correction algorithm is based on the Singular Value Decomposition (SVD) of the orbit response matrix. For performance tuning and additional flexibility when adding or removing Corrector Magnets (CM) and Beam Position Monitors (BPMs), we impleme...
متن کاملInhibition of fatty acids profile changes of Cobia (Rachycentron canadum) fillets during frozen storage by packaging under vacuum system
This study was aimed to investigate the effect of vacuum packing (VP) on the fatty acids profiles in cobia (Rachycentron canadum) fillets during an extended frozen storage period. Cobia fillets were treated under vacuum system then stored at -18°C for up to 6 months and compared to control conditions. As a result of a frozen storage period of 6 months, a marked content decrease was found in the...
متن کاملSpear2 Rf Operation: a Bridge to Spear3*
The present schedule calls for the Spear2 RF system operation until March of 2003, when it will be dismantled to make room for the Spear3. While any new investment to improve the system is discouraged for this limited-time operation, efforts are focused on maintaining the system reliability and accommodating any changes necessitated by new construction in preparation for the Spear3. In this pap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999