The Results of Volar Locking Plate Fixation for the Fragility Fracture Population with Distal Radius Fracture in Japanese Women

نویسندگان

  • SHUICHI KATO
  • MASAHIRO TATEBE
  • MICHIRO YAMAMOTO
  • KATSUYUKI IWATSUKI
  • TAKANOBU NISHIZUKA
  • HITOSHI HIRATA
چکیده

The purpose of this study was to determine whether volar locking plate fixation for distal radius fracture benefits the fragility fracture population as much as it benefits the non-fragility fracture population. This matched case-control study was conducted based on a multi-center clinical prospective cohort. A comparison of treatment outcomes after volar locking plate fixation was made between females 55 years of age and older (fragility fracture population) and males less than 75 years of age (non-fragility fracture population) by evaluating clinical, radiological, and subjective outcomes using Hand20, a validated patient-rated disability instrument. A total of 170 patients were enrolled in this study. The two cohorts were matched in terms of AO fracture type. The fragility fracture population group and the non-fragility fracture population group each consisted of 50 patients. All objective measurements including wrist range of motion and radiological evaluations, but excluding grip strength, were not significantly different between the two groups. However, the Hand20 at 18 months after surgery was worse in the fragility fracture population group than in the non-fragility fracture population group. Carpal tunnel syndrome was the most frequently encountered complication in the fragility fracture population group, with one case (2%) in the non-fragility fracture population group and six cases (12%) in the fragility fracture population group, but the difference was not significant. In conclusion, there was a significant deficit in the improvement in disability despite favorable radiological and functional outcomes in fragility fracture population patients. Therefore, the fragility fracture population, especially middle-aged or older women, needs to be informed about prolonged disability and the higher risk of upper extremity disorders prior to surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis

Objective: The superiority of volar locking plate fixation and K-wire fixation on treatment of distal radius fractures was controversial. Thus, we performed a meta-analysis to compare the efficacy of volar locking plate and K-wires for distal radius fracture. Methods: We searched Embase, Medline and PubMed for randomized controlled trials which compare the effects of volar locking plate and K-w...

متن کامل

Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...

متن کامل

Economic Analysis of Bisphosphonate Use after Distal Radius Fracture for Prevention of Hip Fracture

Background: Osteoporosis is a common condition among the elderly population, and is associated with an increased risk of fracture. One of the most common fragility fractures involve the distal radius, and are associated with risk of subsequent fragility fracture. Early treatment with bisphosphonates has been suggested to decrease the population hip fracture burden. However, there have been no p...

متن کامل

Devising for a distal radius fracture fixation focus on the intra-articular volar dislocated fragment

INTRODUCTION Distal radius fracture (DRF) accompanied by intra-articular volar displaced fragment is difficult to reduce. This volar fragment remains when treated with a simple buttress effect alone, and V-shaped deformity may remain on the articular surface. We attempted to improve dorsal rotational deviation of volar fragment by osteosynthesis applying the condylar stabilizing technique. We r...

متن کامل

Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability.

BACKGROUND Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted extra-articular distal radial fractures. The purpose of the present study was to compare the relative stability of five distal radial plates (four volar and one dorsal), all of which are commonly used for the treatme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 76  شماره 

صفحات  -

تاریخ انتشار 2014