Semi-automated quantification of hard exudates in colour fundus photographs diagnosed with diabetic retinopathy

نویسندگان

  • Abhilash Goud Marupally
  • Kiran Kumar Vupparaboina
  • Hari Kumar Peguda
  • Ashutosh Richhariya
  • Soumya Jana
  • Jay Chhablani
چکیده

BACKGROUND Hard exudates (HEs) are the classical sign of diabetic retinopathy (DR) which is one of the leading causes of blindness, especially in developing countries. Accordingly, disease screening involves examining HEs qualitatively using fundus camera. However, for monitoring the treatment response, quantification of HEs becomes crucial and hence clinicians now seek to measure the area of HEs in the digital colour fundus (CF) photographs. Against this backdrop, we proposed an algorithm to quantify HEs using CF images and compare with previously reported technique using ImageJ. METHODS CF photographs of 30 eyes (20 patients) with diabetic macular edema were obtained. A robust semi-automated algorithm was developed to quantify area covered by HEs. In particular, the proposed algorithm, a two pronged methodology, involved performing top-hat filtering, second order statistical filtering, and thresholding of the colour fundus images. Subsequently, two masked observers performed HEs measurements using previously reported ImageJ-based protocol and compared with those obtained through proposed method. Intra and inter-observer grading was performed for determining percentage area of HEs identified by the individual algorithm. RESULTS Of the 30 subjects, 21 were males and 9 were females with a mean age of the 50.25 ± 7.80 years (range 33-66 years). The correlation between the two measurements of semi-automated and ImageJ were 0.99 and 0.99 respectively. Previously reported method detected only 0-30% of the HEs area in 9 images, 30-60% in 12 images and 60-90% in remaining images, and more than 90% in none. In contrast, proposed method, detected 60-90% of the HEs area in 13 images and 90-100% in remaining 17 images. CONCLUSION Proposed method semi-automated algorithm achieved acceptable accuracy, qualitatively and quantitatively, on a heterogeneous dataset. Further, quantitative analysis performed based on intra- and inter-observer grading showed that proposed methodology detects HEs more accurately than previously reported ImageJ-based technique. In particular, we proposed algorithm detect faint HEs also as opposed to the earlier method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Author’s response to reviews Title: Semi-automated quantification of hard exudates in colour fundus photographs diagnosed with diabetic retinopathy Authors:

Title: Semi-automated quantification of hard exudates in colour fundus photographs diagnosed with diabetic retinopathy Authors: Abhilash Marupally ([email protected]) Kiran Vupparaboina ([email protected]) Hari Peguda ([email protected]) Ashutosh Richhariya ([email protected]) Soumya Jana ([email protected]) Jay Chhablani ([email protected]) Version: 1 Date: 17 Aug 2017 Author’s...

متن کامل

Computerized Exudate Detection in Fundus Images Using Statistical Feature based Fuzzy C-mean Clustering

Diabetic retinopathy(DR) is considered as the root cause of vision loss for diabetic patients .One of the greatest concern and immediate challenges to the current health care is the severe progression of diabetes. Diabetic retinopathy is an eye disease and appearance of hard exudates is one of its earliest signs. The accuracy of the automated disease identification techniques should be high .Be...

متن کامل

An Efficient Integrated Approach for the Detection of Exudates and Diabetic Maculopathy in Colour fundus Images

Diabetic Retinopathy (DR) is a major cause of blindness. Exudates are one of the primary signs of diabetic retinopathy which is a main cause of blindness that could be prevented with an early screening process In this approach, the process and knowledge of digital image processing to diagnose exudates from images of retina is applied. An automated method to detect and localize the presence of e...

متن کامل

Fine structure in diabetic retinopathy lesions as observed by adaptive optics imaging. A qualitative study.

PURPOSE Diabetic retinopathy is diagnosed by fundus photography and optical coherence tomography (OCT) scanning. However, adaptive optics (AO) imaging can be expected to add new aspects to the knowledge of diabetic retinopathy because photographic resolution is improved by reducing the influence of optical aberrations on retinal imaging. METHODS Nineteen patients with diabetes mellitus were s...

متن کامل

Automated Segmentation of Hard Exudates Using Dynamic Thresholding to Detect Diabetic Retinopathy in Retinal Photographs

Retinal images are in use by ophthalmologists for the clinical analysis and diagnosis of different retinal diseases. The ocular disease known as Diabetic Retinopathy (DR) is a retinal disease that causes microvascular changes in the eye retina. Hard Exudates (HE) a retinal lesion can be seen as bright yellowish spots in colored fundus photograph and as bright white blobs in red free fundus imag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017