Continuous glucose monitoring system: dawn period calibration does not change accuracy of the method.

نویسندگان

  • Gustavo A Augusto
  • André G P Sousa
  • Marcela N A Perazo
  • Maria L C Correa-Giannella
  • Marcia Nery
  • Karla F S de Melo
چکیده

INTRODUCTION Continuous glucose monitoring system is a valuable instrument to measure glycemic control, which uses a retrospective calibration based upon 3 to 4 capillary glucose meter values inserted by the patient each day. OBJECTIVE We evaluated the interference of calibration during the dawn period in the system accuracy. METHODS The monitoring data were retrospectively divided into two groups: with (Group A) or without (Group B) the dawn period calibration (between 1:00 and 5:00 AM). Accuracy of the method was expressed by relative absolute difference. RESULTS Thirty-four continuous glucose monitoring data were evaluated comprising a total of 112 nights. A total of 289 paired readings were analyzed - 195 in Group A and 94 in Group B. We did not find a difference in relative absolute difference (RAD%) in any analyzed period of day by adding dawn calibration. CONCLUSIONS These data suggest that dawn calibration does not alter accuracy of method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How Can We Realize the Clinical Benefits of Continuous Glucose Monitoring?

Controlling glycemia in diabetes remains key to prevent complications in this condition. However, glucose levels can undergo large fluctuations secondary to daily activities, consequently creating management difficulties. The current review summarizes the basics of glucose management in diabetes by addressing the main glycemic parameters. The advantages and limitation of HbA1c, the gold standar...

متن کامل

Pilot study of a prototype minimally invasive intradermal continuous glucose monitor.

INTRODUCTION The purpose of this study was to assess point accuracy, rate-of-change accuracy, and safety of a prototype, minimally invasive continuous glucose monitoring (CGM) device over a 12 h in-clinic study. The CGM system consisted of a wireless electronics module with a disposable glucose sensor attached to the bottom. The electronics module was affixed to the abdomen using an adhesive pa...

متن کامل

Optical Analyzer for Continuous Monitoring of Dissolved Oxygen in Aviation Fuel and Other Non-aqueous Media

A special sensitive element based on the novel composite material was created. The sensor has a linear calibration and is resistant to aliphatic hydrocarbons, in particular aviation fuel. A low cost and easy-to-implement method for calibrating the sensor was proposed. Temperature dependence of the oxygen mass transfer coefficient kL was measured for aviation fuel TS-1 (Russi...

متن کامل

Accuracy of the SEVEN continuous glucose monitoring system: comparison with frequently sampled venous glucose measurements.

BACKGROUND The purpose of this study was to compare the accuracy of measurements obtained from the DexCom SEVEN system with Yellow Springs Instrument (YSI) laboratory measurements of venous blood glucose. METHODS Seventy-two subjects with insulin-requiring diabetes, aged 18-71, were enrolled in a multicenter, prospective single-arm study. All participants wore the SEVEN continuous glucose mon...

متن کامل

Continuous glucose monitoring considerations for the development of a closed-loop artificial pancreas system.

BACKGROUND Commercialization of a closed-loop artificial pancreas system that employs continuous subcutaneous insulin infusion and interstitial fluid glucose sensing has been encumbered by state-of-the-art technology. Continuous glucose monitoring (CGM) devices with improved accuracy could significantly advance development efforts. However, the current accuracy of CGM devices might be adequate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arquivos brasileiros de endocrinologia e metabologia

دوره 53 4  شماره 

صفحات  -

تاریخ انتشار 2009