The influence of mechanical input parameters on the duration of the mandibular joint electromyographic silent period in man.
نویسندگان
چکیده
The duration of the electromyographic silent period following a tap to the menton has been reported to be clinically useful in the diagnosis of mandibular joint dysfunction but not the influence of details of the tap. Using a solenoid-driven mechanical tapper, the following were investigated: in patients with joint dysfunction, effect on single muscles and position of the tap in a sequence of taps, in normal subjects, force of the tap, degree of opening of the jaw, angle of tap, and the biting force; all on the duration of the resulting silent period. No significant changes could be ascribed to any of these variables. The introduction between the teeth of wooden shims or a bite-force transducer were the only factors to change the duration. The dysfunction group had significantly longer silent periods than the normal group. It is concluded that, provided nothing is introduced between the teeth, the input parameters investigated do not influence the duration of the silent period.
منابع مشابه
The Influence of Heat-Input on Structural and Mechanical Properties of 2205 Duplex Stainless Steel
The influence of heat-input and pre-heat treatment on the structure, mechanical and corrosion behaviors of 2205 duplex stainless steel joint by means of GMAW process was the goal of this study. In this regards, the welding process was done using different heat input in the range of 0.6 to 1.4 kJ/mm and different pre-heating treatments in the range of 25 to 100 oC. The microstructural properties...
متن کاملThe Influence of Heat-Input on Structural and Mechanical Properties of 2205 Duplex Stainless Steel
The influence of heat-input and pre-heat treatment on the structure, mechanical and corrosion behaviors of 2205 duplex stainless steel joint by means of GMAW process was the goal of this study. In this regards, the welding process was done using different heat input in the range of 0.6 to 1.4 kJ/mm and different pre-heating treatments in the range of 25 to 100 oC. The microstructural properties...
متن کاملOn the Influence of Riveting Process Parameters on Fatigue Life of Riveted Lap Joint
In this paper, influence of riveting process parameters, namely, riveting force, sheet thickness, friction coefficient and clearance fit are investigated on residual stress field and fatigue life of single riveted lap joint of AA2024 type. According to the effect of riveting induced residual stresses on fatigue life of riveted lap joint, these parameters are optimized to maximize the residual s...
متن کاملElectrodiagnosis at median occlusal position for human subjects with mandibular joint syndrome.
~~Neuromuscular inhibitory effects were monitored in the temporalis and masseter muscles for ten patients with mandibular joint (MJ) syndrome. and ten control subjects with normal occlusions. Analysis of the electromyographic (EMG) silent period in the controls showed no significant difference between durations at median occlusal position, following placement of a maxillary acrylic occlusal spl...
متن کاملFinite element simulation of the clinching process of steel sheets and study on influence of anisotropy on the mechanical behavior of joint
This article describes a numerical study on the TOX-clinching process of the steel sheets. In addition, the influence of plastic anisotropy of the material on joining parameters is analyzed by evolution of the joint parameters such as undercut and neck thickness and punch force-displacement curve. Finite element analysis with ABAQUS/CAE-Explicit program is used to simulate two dimensional and t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archives of oral biology
دوره 22 10-11 شماره
صفحات -
تاریخ انتشار 1977