Cyclic loading biomechanical analysis of the pullout strengths of rotator cuff and glenoid anchors: 2013 update.

نویسندگان

  • F Alan Barber
  • Morley A Herbert
چکیده

PURPOSE The purpose of this study was to evaluate the biomechanical and design characteristics of newer suture anchors under cyclic loading. METHODS Suture anchors were tested in fresh porcine cortical and cancellous bone by cyclic loading (10 to 100 N for 200 cycles) followed by destructive testing parallel to the insertion axis at 12.5 mm per second. End points included ultimate failure load, displacement at 100 and 200 cycles, failure mode, and stiffness. Anchors tested included ReelX (Stryker Endoscopy, San Jose, CA); Footprint Ultra PK (4.5 and 5.5 mm) (Smith & Nephew, Andover, MA); TwinFix (4.5, 5.5, and 6.5 mm made from polyether ether ketone [PEEK], hydroxyapatite [HA], and titanium [Ti]) (Smith & Nephew Endoscopy, Andover, MA); Morphix (2.5 and 5.5 mm) (MedShape Solutions, Atlanta, GA); CrossFT BC (ConMed-Linvatec, Largo, FL); JuggerKnot (1.5 and 2.8 mm) (Biomet Sports Medicine, Warsaw, IN); Healicoil (Smith & Nephew Endoscopy, Andover, MA); Quattro (X, Link, and GL) (Cayenne Medical, Scottsdale, AZ); Healix (Biocryl Rapide [BR], PEEK, and Ti) (DePuy Mitek, Raynham, MA); Twin Loop (3.5 mm, PEEK) (Stryker Endoscopy, San Jose, CA); PressFT (2.1 and 2.6 mm) (ConMed Linvatec, Largo FL); Y-Knot (ConMed Linvatec, Largo FL); Gryphon (BR and PEEK) (DePuy Mitek, Raynham, MA); and Iconix (1, 2, and 3) (Stryker Endoscopy, San Jose, CA). RESULTS Rotator cuff anchors showed greater failure loads than did glenoid anchors in metaphyseal bone (rotator cuff anchors 448 N v glenoid anchors 296 N) (P = .001) and cancellous bone (rotator cuff anchors 435 N v glenoid anchors 225 N) (P < .001). No anchors reached 5 mm of displacement during cyclic loading. TwinFix anchors showed greater displacement at 100 (P = .014) and 200 cycles (P = .036) than did other rotator cuff anchors, although the ReelX and Morphix showed the greatest displacements. Rotator cuff anchors failed principally by eyelet breaking, whereas glenoid anchors failed more often by anchor pullout than by any other mode. No differences in stiffness were observed across the different rotator cuff and glenoid anchors tested. CONCLUSIONS Rotator cuff anchors showed higher failure strengths than did glenoid anchors, regardless of bone type. TwinFix anchors showed more cyclic displacement than did other rotator cuff anchors (except the ReelX and Morphix anchors) and the glenoid anchors tested. The failure mode was dependent on the specific anchor. CLINICAL RELEVANCE Suture anchor constructs tested showed that failure load is dependent on anchor type (rotator cuff anchor or glenoid anchor) but not on anchor location (cancellous or cortical bone).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Evaluation of Rotator Cuff Repair Complex: Single vs. Double Row Repair

INTRODUCTION: Current rotator cuff repairs have a high incidence of asymptomatic defects [1]. Researchers have quantified that current repairs only restore a maximum of 67% of the original footprint of the rotator cuff [2]. Recently, double row suture anchors repair techniques have been reported that could re-establish the footprint of the rotator cuff [3,4]. Reports have shown that the biomech...

متن کامل

Knotless single-row rotator cuff repair: a comparative biomechanical study of 2 knotless suture anchors.

The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the ...

متن کامل

Biomechanical performance of rotator cuff repairs with humeral rotation: a new rotator cuff repair failure model.

BACKGROUND Traditional biomechanical evaluations of rotator cuff repair techniques employ cyclic loading of the supraspinatus tendon in an isolated medial direction. PURPOSE This study was conducted to evaluate 2 different rotator cuff repair techniques that are currently the subject of debate with cyclic loading and with internal and external humeral rotation to better simulate postoperative...

متن کامل

Biomechanical evaluation of transosseous rotator cuff repair: do anchors really matter?

BACKGROUND Suture anchor fixation has become the preferred method for arthroscopic repairs of rotator cuff tears. Recently, newer arthroscopic repair techniques including transosseous-equivalent repairs with anchors or arthroscopic transosseous suture passage have been developed. PURPOSE To compare the initial biomechanical performance including ultimate load to failure and localized cyclic e...

متن کامل

Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model.

BACKGROUND To further reduce the invasiveness of arthroscopic rotator cuff repair surgery the all-suture anchor has been developed. The all-suture anchor requires less bone removal and reduces the potential of loose body complications. The all-suture anchor must also have adequate biomechanical strength for the repair to heal. The hypothesis is there is no significant difference in the biomecha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 2013