Cerebral blood flow effects of pain and acupuncture: a preliminary single-photon emission computed tomography imaging study.

نویسندگان

  • Andrew B Newberg
  • Patrick J Lariccia
  • Bruce Y Lee
  • John T Farrar
  • Lorna Lee
  • Abass Alavi
چکیده

BACKGROUND The purpose of this study was to investigate the cerebral blood flow changes associated with the analgesic effect of acupuncture in patients with chronic pain. METHODS Seven patients presenting with a chronic pain syndrome and 5 healthy controls were included. All single-photon emission computed tomography (SPECT) scans were acquired with a uniform protocol. The patient group was injected with the radioisotope hexamethyl propyleneamine oxime (HMPAO) while experiencing their usual level of pain. A baseline scan was acquired approximately 20 minutes after administration of the HMPAO. The patient then underwent acupuncture therapy with needles placed in points specifically selected to relieve pain. When the pain improved, as determined by a 10-digit score for pain assessment, the patient was reinjected with HMPAO and imaged 20 minutes later for the acupuncture scan. The reference group also had a baseline and acupuncture scan, although the acupuncture itself was performed using a standardized set of needle points. RESULTS The reference group participants were found to have significant increases in the thalamic and prefrontal cortex activity on the acupuncture scan compared to the baseline. The baseline scans of the pain patients showed significant asymmetric uptake in the thalami compared to controls. This asymmetry reversed or normalized after the acupuncture therapy. Significant correlations were observed between the change of activity in the prefrontal cortex and ipsilateral sensorimotor area. CONCLUSION The results from these cases show that HMPAO-SPECT is capable of detecting changes in cerebral blood flow associated with pain and that acupuncture analgesia is associated with changes in the activity of the frontal lobes, brain stem, and thalami.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abnormal cerebral blood flow in methamphetamine abusers assessed by brain perfusion single emission computed tomography

Introduction:Amphetamines are central nervous system (CNS) stimulant substances and amphetamine abuse is considered a growing problem in our country. Previous studies revealed destructive effects of amphetamines on metabolism, perfusion and structure of brain. The aim of current study was evaluating regional cerebral blood flow (rCBF) disturbances in methamphetamine (MA) abuser...

متن کامل

Neural Imaging Using Single-Photon Avalanche Diodes

Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimumdark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging pro...

متن کامل

Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review

Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Imaging of cerebral blood flow markers in Huntington's disease using single photon emission computed tomography.

Single photon emission computed tomography (SPECT) imaging of six Huntington's disease patients revealed a striking reduction in regional uptake of cerebral blood flow markers in vivo. Similar changes were found in one patient with "early stage" disease. The findings are compared with parallel magnetic resonance imaging (MRI) studies, and in one case, results of postmortem examination.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of neuroimaging : official journal of the American Society of Neuroimaging

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2005