Open versus Percutaneous Stabilization of Thoracolumbar Spine Fractures: A Short-Term Functional and Radiological Follow-up.

نویسندگان

  • M Pishnamaz
  • S Oikonomidis
  • M Knobe
  • K Horst
  • H-C Pape
  • P Kobbe
چکیده

PURPOSE OF THE STUDY A prospective cohort study evaluates the functional and radiological outcome of thoracolumbar spine fractures treated either with open or percutaneous dorsal instrumentation. In recent years, several studies advocate percutaneous stabilization of spinal fractures in patients without neurological deficits. However, it is still debated whether percutaneous stabilization is superior to open dorsal instrumentation in spinal trauma. MATERIAL AND METHODS This study was performed between 2010 and 2012 at a Level 1 trauma center. Patients treated either with an open or a percutaneous dorsal instrumentation for traumatic fractures of the thoracolumbar spine (T11 to L2) were included. Fracture morphology, screw positioning and clinical parameters were analyzed. Standardized questionnaires (VAS-spine-score; Oswestry-disability-score; SF-36) and follow up radiographs were performed. RESULTS Overall 72 patients (29 percutaneous; 43 open) could be included. The surgical and the early postsurgical course were similar between both groups. Furthermore the operative approach had no influence on the functional and radiological outcome one year after surgery, but the questionnaires showed moderate impairments within both groups. Also both groups showed a significant loss of reduction after the first postoperative month (p < 0.01). Within the open group a significantly higher amount of fracture reduction (p < 0.01) and a significantly reduced intraoperative radiation exposure was seen (open 105.9 sec.; percutaneous 143.1 sec; p < 0.05); whereas the percutaneous approach was associated with significantly reduced intraoperative blood loss (open 2.2 g/dl; percutaneous 1.2 g/dl; p < 0.001). CONCLUSION The functional and the radiological outcome of both groups was comparable one year after trauma. Minor advantages of the percutaneous system was less blood loss, whereas the open approach was associated with a significantly higher amount of initial reduction and significantly less intraoperative radiation exposure. Independent from the type of posterior fixation loss of reduction was already significant in the early postoperative course.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Unstable Thoracolumbar Burst Fractures by Indirect Reduction and Posterior Stabilization: Short-Segment Versus Long-Segment Stabilization

In order to compare short-segment stabilization with long-segment stabilization for treating unstable thoracolumbar fractures, we studied fifty patients suffered from unstable thoracolumbar burst fractures. Thirty of them were managed with long-segment posterior transpedicular instrumentation and twenty patients with short-segment stabilization. The mean follow up period was 5.2 years. Pre-oper...

متن کامل

Radiological outcome of short segment posterior stabilisation and fusion in thoracolumbar spine acute fracture.

INTRODUCTION The optimal management of thoracolumbar spine fractures remains a matter of controversy. The current literature implies that the use of short-segment pedicle screw fixation may be inappropriate because of its high reported failure rate. The purpose of this study is to report the short-term results of thoracolumbar burst and compression fractures treated with short-segment pedicle i...

متن کامل

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

 Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...

متن کامل

Percutaneous Vertebroplasty versus Conservative Treatment for One Level Thoracolumbar Osteoporotic Compression Fracture: Results of an Over 2-Year Follow-up.

We retrospectively compared the clinical and radiological results of percutaneous vertebroplasty with those of conservative treatment in the management of thoracolumbar osteoporotic compression fractures. Sixty-five patients who could be followed up for more than 2 years with thoracic and lumbar spine osteoporotic compression fractures, between January 2005 and October 2010, were reviewed. The ...

متن کامل

Minimal Invasive Circumferential Management of Thoracolumbar Spine Fractures

INTRODUCTION While thoracolumbar fractures are common lesions, no strong consensus is available at the moment. OBJECTIVES The aim of this study was to evaluate the results of a minimal invasive strategy using percutaneous instrumentation and anterior approach in the management of thoracolumbar unstable fractures. METHODS 39 patients were included in this retrospective study. Radiologic eval...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca

دوره 82 4  شماره 

صفحات  -

تاریخ انتشار 2015