A novel system for continuous, real-time monitoring of heart motion signals
نویسندگان
چکیده
BACKGROUND Understanding cardiac mechanics is important for developing cardiac therapies. Current modalities for assessing cardiac mechanics sample patient's heart at specific heart rate, contractility, preload, and afterload. The objective of this study was to test the feasibility of a novel system composed of intra-cardiac leads equipped with an inertial module chip (3D accelerometers and 3D gyroscopes) in monitoring continuous heart motion. METHODS In this descriptive study, four healthy pigs were anesthetized and instrumented with motion-sensitive intra-cardiac leads; the temporal correlation between signals from motion sensors and tissue Doppler from the chest wall were studied; changes in real-time heart accelerations (ACC) and angular velocity (ANGV) were reported as percentages of change from baseline. RESULTS Heart motion signals were sensed continuously from the right ventricular apex (RVa) and coronary sinus (CS). Volume expansion did not produce significant changes in the ACC and ANGV signals. Increasing heart rate increased the peak systolic ACC signal recorded from RVa and CS by 94 and 76%, respectively, and increased both peak systolic (61% RVa and 27% CS) and diastolic ANGV (200% CS vs. 31% RVa). Epinephrine administration increased peak systolic ACC signals at both sites (246% RVa; 331% CS). Peak systolic and diastolic ANGV increased in response to epinephrine (systolic: 198% RVa and 175% CS; diastolic: 723% CS and 89% RVa) (p = 0.125 for all changes expressed in percent). Temporal correlation between the ANGV signal and tissue Doppler signal was detected throughout all interventions. CONCLUSIONS A novel system for continuously monitoring heart motion signals from within the heart was presented. Heart motion signals in response to physiologic manipulations were characterized.
منابع مشابه
A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملDesigning and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals
Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...
متن کاملReal-time acoustic tomography system and the experience of Caspian current sea monitoring
The Acoustic Tomography (AT) systems are used to monitor long-term and continuous flow in rivers, seas and oceans. One of the disadvantages of existing systems in Iran is the inability of real-time/automated measurements. In this study, by adding a raspberry Pi computer to the system and performing the required programming, it was possible to do online monitoring. The data are transferred to th...
متن کاملProposed new signal for real-time stress monitoring: Combination of physiological measures
Human stress is a physiological tension that appears when a person responds to mental, emotional, or physical chal-lenges. Detecting human stress and developing methods to manage it, has become an important issue nowadays. Au-tomatic stress detection through physiological signals may be a useful method for solving this problem. In most of the earlier studies, long-term time window was considere...
متن کاملA Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia
Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...