Performance of calibration standards for antigen quantitation with flow cytometry.

نویسندگان

  • R Lenkei
  • J W Gratama
  • G Rothe
  • G Schmitz
  • J L D'hautcourt
  • A Arekrans
  • F Mandy
  • G Marti
چکیده

In the frame of the activities initiated by the Task Force for Antigen Quantitation of the European Working Group on Clinical Cell Analysis (EWGCCA), an experiment was conducted to evaluate microbead standards used for quantitative flow cytometry (QFCM). An unified window of analysis (UWA) was established on three different instruments (EPICS XL [Coulter Corporation, Miami, FL], FACScan and FACS Calibur [Becton Dickinson, San Jose, CA]) with QC3 microbeads (FCSC, PR). By using this defined fluorescence intensity scale, the performance of several monoclonal antibodies directed to CD3, CD4, and CD8 (conjugated and unconjugated), from three manufacturers (BDIS, Coulter [Immunotech], and DAKO) was tested. In addition, the QIFI system (DAKO) and QuantiBRITE (BDIS), and a method of relative fluorescence intensity (RFI, method of Giorgi), were compared. mAbs reacting with three more antigens, CD16, CD19, and CD38 were tested on the FACScan instrument. Quantitation was carried out using a single batch of cryopreserved peripheral blood leukocytes, and all tests were performed as single color analyses. Significant correlations were observed between the antibody-binding capacity (ABC) values of the same CD antigen measured with various calibrators and with antibodies differing in respect to vendor, labeling and possible epitope recognition. Despite the significant correlations, the ABC values of most monoclonal antibodies differed by 20-40% when determined by the different fluorochrome conjugates and different calibrators. The results of this study indicate that, at the present stage of QFCM consistent ABC values may be attained between laboratories provided that a specific calibration system is used including specific calibrators, reagents, and protocols.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorescent erythrocyte ghosts as standards for quantitative flow cytometry.

We report here a quick and inexpensive method for preparing standards of known fluorochrome content for calibration and quantitation of flow cytometry fluorescence signals. Erythrocyte ghosts prepared by hypotonic lysis are filled with solutions containing fluorescently labeled dextran. Standards prepared by this technique have a narrow range of fluorescence and a linear response of fluorescenc...

متن کامل

Quantitative measurement of multifunctional quantum dot binding to cellular targets using flow cytometry.

Semiconductor nanocrystals such as quantum dots (QDs) are a potentially powerful resource in the fields of flow cytometry and fluorescence microscopy. QD size and fluorescence characteristics offer attractive features for use in targeted delivery systems and detection by flow cytometry. While quantitative measurements of a variety of fluorescent molecules are routinely performed, fluorophores f...

متن کامل

Quantification of cell surface proteins with bispecific antibodies

Flow cytometry is an established method for fast and accurate quantitation of cellular protein levels and requires fluorescently labeled antibodies as well as calibration standards. A critical step for quantitation remains the production of suitable detection antibodies with a precisely defined ratio of antigen-binding sites to fluorophores. Problems often arise as a consequence of inefficient ...

متن کامل

Measurement of Lipid Accumulation in Chlorella vulgaris via Flow Cytometry and Liquid-State 1H NMR Spectroscopy for Development of an NMR-Traceable Flow Cytometry Protocol

In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as ...

متن کامل

Measurement of Lipid Accumulation in Chlorella vulgaris via Flow Cytometry and Liquid-State ¹H NMR Spectroscopy for Development of an NMR-Traceable Flow Cytometry Protocol

In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cytometry. Part B, Clinical cytometry

دوره 72 6  شماره 

صفحات  -

تاریخ انتشار 1998