Improvement of the SNR and resolution of susceptibility-weighted venography by model-based multi-echo denoising
نویسندگان
چکیده
The vein structures of the brain are important for understanding brain function and structure, especially when functional magnetic resonance imaging (fMRI) is utilized, as fMRI is based on changes in the blood-oxygen-level-dependent (BOLD) signal, which is directly related to veins. The aim of the present study was to develop an effective method to produce high signal-to-noise-ratio (SNR) and high-resolution multi-contrast susceptibility-weighted (SW) images of vein structures from 3T magnetic resonance (MR) scanners using multi-gradient-echo MR acquisition and a successive denoising process for both magnitude and phase data. Successive multi-echo MR images were acquired at multiple time points using a multigradient-recalled echo sequence at 3T, and noise in the magnitude and phase data was effectively suppressed using model-based denoising methods. A T(2)* relaxation model was used to denoise the magnitude data and a linear phase model was used to denoise the phase data. SW venography images were obtained from the denoised MR data and compared with conventional SW venography. To evaluate the performance of our denoising methods, we conducted numerical simulation studies and compared the mean-squared-error (MSE), SNR, and contrast-to-noise ratio (CNR) that we obtained using our procedure with those obtained using conventional denoising methods. In addition, images were inspected visually. Numerical simulations showed that our proposed model-based denoising methods were the most effective at suppressing noise. In vivo experiments also showed a substantial increase in the SNR of the phase mask obtained using the proposed denoising process (twice that of the conventional GRE-based phase mask). The T(2)* relaxation model method improved the SNR of the magnitude image (1.17-1.35 times that of the GRE-based magnitude image). Noise suppression of both magnitude and phase data using our proposed method resulted in an overall increase in the SNR and CNR in the final SW venography (1.1-1.5-fold and 1.96-fold higher SNR and CNR, respectively, than that of the GRE-based SW venography). We demonstrated that high SNR and high-resolution SW venograms can be obtained using multi-echo gradient-recalled acquisition and successive model-based denoising of both magnitude and phase data.
منابع مشابه
High-Contrast and High-SNR SWI Venography with Multiple Echo datasets
Introduction Susceptibility Weighted Imaging (SWI) method is commonly used for Magnetic Resonance (MR) venography. The difference between SWI and conventional GRE imaging is that phase information of signal is incorporated to enhance contrast of image. The phase can provide excellent contrast between venous blood vessels and other tissues with susceptibilities that are different from the backgr...
متن کاملMultiband multi-echo imaging of simultaneous oxygenation and flow timeseries for resting state connectivity
A novel sequence has been introduced that combines multiband imaging with a multi-echo acquisition for simultaneous high spatial resolution pseudo-continuous arterial spin labeling (ASL) and blood-oxygenation-level dependent (BOLD) echo-planar imaging (MBME ASL/BOLD). Resting-state connectivity in healthy adult subjects was assessed using this sequence. Four echoes were acquired with a multiban...
متن کاملPlatelet-based MPLE algorithm for denoising of SPECT images: phantom and patient study
Introduction: In this study the evaluation of a Platelet-based Maximum Penalized Likelihood Estimation (MPLE) for denoising SPECT images was performed and compared with other denoising methods such as Wavelets or Butterworth filtration. Platelet-based MPLE factorization as a multiscale decomposition approach has been already proposed for better edges and surfaces representation due to Poi...
متن کاملImproving Signal-to-Noise Ratio in Susceptibility Weighted Imaging: A Novel Multicomponent Non-Local Approach
In susceptibility-weighted imaging (SWI), the high resolution required to obtain a proper contrast generation leads to a reduced signal-to-noise ratio (SNR). The application of a denoising filter to produce images with higher SNR and still preserve small structures from excessive blurring is therefore extremely desirable. However, as the distributions of magnitude and phase noise may introduce ...
متن کاملImproving Parameter Mapping in MRI Relaxometry and Multi-Echo Dixon using an Automated Spectral Denoising
Synopsis Magnitude-based parameter ᴀ밄tting is commonly used for relaxometry and multi-echo Dixon but introduces a bias for relaxation and fat fraction estimates, particularly for a low signal-to-noise ratio and high relaxation. The application of an automated, patchwise denoising to the multi-echo image series prior to parameter ᴀ밄tting, considerably increased the SNR; thus, reducing the bias a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NeuroImage
دوره 70 شماره
صفحات -
تاریخ انتشار 2013