Basic design and construction of the Vienna FES implants: existing solutions and prospects for new generations of implants.
نویسندگان
چکیده
We can distinguish 3 generations of FES implants for activation of neural structures: 1. RF-powered implants with antenna displacement dependent stimulation amplitude; 2. RF-powered implants with stabilised stimulation amplitude; and 3. battery powered implants. In Vienna an 8-channel version of the second generation type has been applied clinically to mobilisation of paraplegics and phrenic pacing. A 20-channel implant of the second generation type for mobilisation of paraplegics and an 8-channel implant of the third generation type for cardiac assist have been tested in animal studies. A device of completely new design for direct stimulation of denervated muscles is being tested in animal studies. There is a limited choice of technologically suitable biocompatible and bioresistant materials for implants. The physical design has to be anatomically shaped without corners or edges. Electrical conductors carrying direct current (D.C.) have to be placed inside a hermetic metal case. The established sealing materials, silicone rubber and epoxy resin, do not provide hermeticity and should only embed DC-free components. For electrical connections outside the hermetic metal case welding is preferable to soldering; conductive adhesives should be avoided. It is advisable to use a hydrophobic oxide ceramic core for telemetry antenna coils embedded in sealing polymer. Cleaning of all components before sealing in resin is of the utmost importance as well as avoidance of rapid temperature changes during the curing process.
منابع مشابه
A review on nanostructured stainless steel implants for biomedical application
Over the last two decades, many researchers have developed a variety of stainless steel-based medical implant types,taking full advantage of nanostructuring technologies. In this paper the application, fabrication and development of nanostructured stainless steel based materials with new composition for medical implants will be discussed. It is well established that application of severe plasti...
متن کاملطراحی، تهیه و ارزیابی پوشش نوین هیدروکسی آپاتیت-تیتانیوم برای اندوایمپلنت دندانی
Nowadays, application of implants as a new method for replacing extracted teeth have been improved. So, many researches have been performed for improving the characteristics of implants. The aim of this study was to design and produce a desired coating in order to obtaining two goals including improvement of the corrosion behavior of metallic endodontic implant and the bone osseointegration sim...
متن کاملThe Effect Of Restoration Type On Osseointegration of Dental Implants: A Histological Analysis In Dogs
Background and Objective: The concept of immediate occlusal loading with dental implants offers several advantages. In this research, the effect of type of restoration on Osseointegration rate of dental implants was histologically evaluated. Materials and Methods: Three months prior to implantation, the lower premolar teeth of 15 dogs were extracted. Then, 3 to 4 Maestro™ implants were plac...
متن کاملA novel phantom design for brachytherapy quality assurance
Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...
متن کاملImmediate loading in dental implants ( A literature review )
Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical engineering & physics
دوره 23 1 شماره
صفحات -
تاریخ انتشار 2001