Approximate computation of high-frequency characteristics for power line with horizontal disposition and middle-phase to ground coupling

نویسندگان

  • Nermin Suljanović
  • Aljo Mujčić
  • Matej Zajc
  • Jurij F. Tasič
چکیده

Paper presents an approximate computation of high-frequency high-voltage power-line characteristics: amplitude, phase and group delay characteristic. Analytical approximate formulae are derived for the power line with three conductors in horizontal disposition and middle-phase to ground coupling. Expressions derived from modal analysis and detailed computation methods allow analysis of power-line high-frequency characteristics, like oscillations in high-frequency characteristics due to reflection on the power line. Such formulae are available in the literature for modal propagation functions and power-line amplitude characteristic. However, this paper also treats power-line phase characteristic and group delay important for digital communication systems design that are not thoroughly investigated in analog communications. The paper shows that nonlinearities in the phase characteristic due to reflection are determined with Hilbert transform of the amplitude characteristic. © 2003 Elsevier B.V. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple digital filter implementation of the HV PLC channel model

The paper presents a simple implementation model of the high-voltage power line communication (HV PLC) channel using digital filters. The model utilizes three identical finite impulse response (FIR) filters. The amplitude characteristic of the FIR filters matches the HV PLC channel amplitude characteristic for a given coupling, without taking into consideration reflection. The reflection phenom...

متن کامل

Flexible Power Electronic Transformer for Power Flow Control Applications

This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...

متن کامل

A Novel Generalized Topology for Multi-level Inverter with Switched Series-parallel DC Sources (RESEARCH NOTE)

This paper presents a novel topology of single-phase multilevel inverter for low and high power applications. It consists of polarity (Level) generation circuit and H Bridge. The proposed topology can produce higher output voltage levels by connecting dc voltage sources   in series and parallel. The proposed topology utilizes minimum number of power electronic devices which helps in reduction o...

متن کامل

Phased array antenna using MEMS phase shifter

This article presents a phased array antenna employing MEMS phase shifter. The proposed phased array antenna consists of eight square patch antennas operating at 10.4 GHz with a bandwidth of 400 MHz. Feed line for each patch passes through a MEMS phase shifter realized by a series of bridges above the transmission line. The distance between the bridge and the transmission line underneath it is ...

متن کامل

الگوریتم جامعی برای مکان یابی خطا در خطوط انتقال دو مداره و چند پایانه ای (بیش از سه پایانه) مبتنی بر داده های PMU

A new PMU-based fault detection/location algorithm for multi-terminal transmission lines is proposed in this paper, which works on the basis of synchronized voltage and current phasors received from PMUs installed in various terminals. The Clark transform (for transposed transmission lines), Eigen-values and eigenvectors theory (for un-transposed ones) are used to decouple 3-phase differential ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003