Biomechanical considerations in slipped capital femoral epiphysis and insights into prophylactic fixation

نویسندگان

  • E. Leblanc
  • J. M. Bellemore
  • T. Cheng
  • D. G. Little
  • O. Birke
چکیده

PURPOSE Slipped capital femoral epiphysis (SCFE) is a deformity of the proximal femur secondary to widened and unstable physis. In stabilising the slip, gold standard treatments stop growth and involve premature physeal closure, which prevents the remodelling of the acquired deformity and creates a leg length discrepancy that may be significant in younger patients. METHODS We measured the impact of placing threaded screws across the proximal femoral physis by measuring the centre-trochanteric distance (CTD) and articulo-trochanteric distance (ATD) in participants with or without prophylactic fixation. We then compared the mechanical performance of static (stainless and titanium cannulated Synthes screws) and potentially growing implants (Synthes SCFE screw and Pega Medical Free Gliding screw) in a validated synthetic bone model. RESULTS In the review of 30 non-fixed and 60 fixated hips over a mean follow-up of 1.9 years, we have noted a significant difference in pre/post CTD and ATD, as well as the change in CTD and ATD over time. In the biomechanical study, the newer implants allowing growth (Synthes SCFE screw and Pega Medical Free Gliding screw) were both shown to be at least non-inferior. CONCLUSIONS The primary deformity of a SCFE in itself alters hip mechanics. Also, as confirmed in this study, there is a secondary deformity that is created by static fixation and relative trochanteric overgrowth. To help remodel mild deformities and prevent secondary trochanteric overgrowth, growing implants seem to be non-inferior to the more standard means of fixation in static testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical analysis of single screw fixation for slipped capital femoral epiphysis: are more threads across the physis necessary for stability?

PURPOSE To evaluate single screw fixation stability, in the treatment of slipped capital femoral epiphysis, as a function of screw thread distribution across the physis. STUDY DESIGN In vitro biomechanical study. METHODS Thirty porcine proximal femurs were sectioned through the physeal line and stabilized with a cannulated 7.3-mm stainless steel AO screw. The distal 16 mm of each screw was ...

متن کامل

Biomechanical stability of single-screw versus two-screw fixation of an unstable slipped capital femoral epiphysis model: effect of screw position in the femoral neck.

PURPOSE To biomechanically evaluate single screw and varying 2 screw fixations for an unstable slipped capital femoral epiphysis (SCFE) model using physiologically relevant loading. STUDY DESIGN In vitro biomechanical study. METHODS Twenty-four immature porcine proximal femurs were prepared to simulate a mild-to-moderate unstable SCFE. The femurs were randomized into 4 fixation groups: sing...

متن کامل

C Slipped capital femoral epiphys is

Purpose of review Slipped capital femoral epiphysis is a common adolescent hip disorder. Management of chronic, stable slipped capital femoral epiphysis with in-situ screw fixation has been well defined, but controversy exists regarding management of the unstable hip disorder, the indications for prophylactic fixation of the contralateral hip and the role of osteotomy in the management of resid...

متن کامل

Pinning the slipped and contralateral hips in the treatment of slipped capital femoral epiphysis

PURPOSE To describe and comment on the treatment of the slipped capital femoral epiphysis (SCFE) with pinning and to present the pros and cons of prophylactic pinning of the contralateral hip. SUMMARY Pinning the SCFE aims to fix the epiphysis and prevent further slipping. Some devices allow for further growth and remodeling of the femoral neck post-operatively. This results in maintained fem...

متن کامل

Progressive slip after removal of screw fixation in slipped capital femoral epiphysis: two case reports

UNLABELLED INTRODUCTION In slipped capital femoral epiphysis the femoral neck displaces relative to the head due to weakening of the epiphysis. Early recognition and adequate surgical fixation is essential for a good functional outcome. The fixation should be secured until the closure of the epiphysis to prevent further slippage. A slipped capital femoral epiphysis should not be confused wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017