Interest of fluorescence derivatization and fluorescence probe assisted post-column detection of phospholipids: a short review.
نویسندگان
چکیده
Phospholipids are essential constituents of all living cell membranes. There are many analytical methods available for the quantitative and qualitative determination of phospholipids, but since these molecules lack chromophores, common absorbance based methods are of limited use. Beside mass spectrometry, some less specific approaches that are routinely used are evaporative light scattering detection or fluorescence, which exhibit sufficient sensitivity. Here, we focus on fluorescence, which remains an interesting way to quantify phospholipids. Two ways of detecting phospholipids by fluorescence are possible coupled with separation techniques such as thin layer chromatography (TLC), high performance liquid chromatography (HPLC) and capillary electrophoresis (CE): firstly, pre-column derivatization procedures and secondly, probe assisted post-column detection with suitable fluorescence reagents. In both cases, the common purpose is to increase the detection sensitivity. It is shown that, whereas pre-column derivatization is characterized by selectivity due to the chemical functionality of the analyte involved in the derivatization process, in supramolecular post-column derivatization, the selectivity only proceeds from the capacity of the lipid to involve supramolecular assemblies with a fluorescence probe. The aim of this review is to summarize available experiments concerning fluorescence detection of phospholipids. The interest and limitation of such detection approaches are discussed.
منابع مشابه
Sensitive fluorescence analysis of aflatoxins using post-column UV derivatization on the Agilent 1260 Infinity LC
The analysis of aflatoxins in food matrices such as grain and nuts is an important task for the food industry to ensure product safety. This Application Note shows the analysis of the four major aflatoxins after sample preparation using an immunoaffinity column, post column UV derivatization, and fluorescence detection. We show that with this method the LOD and LOQ required from the regulatory ...
متن کاملA Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملA Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Molecules
دوره 15 1 شماره
صفحات -
تاریخ انتشار 2010