Comparison of glaucomatous visual field defects using standard full threshold and Swedish interactive threshold algorithms.
نویسندگان
چکیده
OBJECTIVES To compare the severity, size, and depth of glaucomatous visual field defects using standard full threshold (FT), Swedish interactive threshold algorithm (SITA) standard (SS), and SITA fast (SF) algorithms of the Humphrey perimeter. METHODS A prospective observational case series of 77 patients with glaucoma performed FT, SS, and SF 30-2 white-on-white testing programs on the same day on 2 occasions for 1 month. The severity of defects was compared using the mean deviation, pattern standard deviation, Advanced Glaucoma Intervention Study, and Hodapp-Anderson-Parrish severity scores. The sizes of defects were compared using the total number of abnormal points on the pattern deviation plot that fit standard criteria for glaucomatous visual field defects. The depths of the defects were compared using the sum of the threshold values for points identified in the pattern deviation plot as fitting criteria for glaucomatous defects. RESULTS The mean deviations were slightly better using the SS (-9.6 +/- 7.1 dB) or the SF (-9.1 +/- 6.7 dB) algorithm compared with the FT algorithm (-10.3 +/- 7.1 dB) (P<.005). There were no significant differences in pattern standard deviations between SS (8.6 +/- 4.0, P =.08) and SF (8.1 +/- 3.6, P =.19) compared with FT (8.3 +/- 3.3), although the pattern standard deviation was higher in SS fields compared with SF fields (P<.001). Advanced Glaucoma Intervention Study scores were slightly better when the SS (7.5 +/- 5.6) or SF (7.2 +/- 5.4) algorithm was used compared with the FT algorithm (8.6 +/- 5.4) (P<.001). The sizes of glaucomatous defects were slightly larger using the SS (20.9 +/- 10.7) algorithm compared with the FT algorithm (19.2 +/- 10.9) (P =.004) but not the SF algorithm (20.0 +/- 10.6) (P =.11). The depth of defects measured by the SS (220.4 +/- 108.0 dB) and SF (219.8 +/- 101.3 dB) algorithms was significantly shallower compared with that measured by the FT algorithm (152.3 +/- 79.1 dB) (P<.001). There were no significant differences in Hodapp-Anderson-Parrish severity scores among algorithms (P =.12). CONCLUSIONS Glaucomatous defects are measured significantly shallower using the new SITA algorithms but are approximately the same size and severity compared with FT measurements. Care should be taken when using threshold values to compare glaucomatous defects in a patient when converting from FT to SITA algorithms.
منابع مشابه
Comparison of Swedish interactive threshold algorithm and full threshold algorithm for glaucomatous visual field loss.
PURPOSE To compare the prevalence of visual field loss, the sensitivity distribution, and the size and depth of glaucomatous visual field defects using the standard full threshold (FT) and the Swedish interactive threshold algorithm (SITA) standard (SS) procedures in patients with early or suspected glaucoma. METHODS Automated perimetry findings were retrospectively evaluated in 53 patients (...
متن کاملDoes the Swedish Interactive Threshold Algorithm (SITA) accurately map visual field loss attributed to vigabatrin?
BACKGROUND Vigabatrin (VGB) is an anti-epileptic medication which has been linked to peripheral constriction of the visual field. Documenting the natural history associated with continued VGB exposure is important when making decisions about the risk and benefits associated with the treatment. Due to its speed the Swedish Interactive Threshold Algorithm (SITA) has become the algorithm of choice...
متن کاملComparison of Different Analytic Algorithms for Interpretation of the Swedish Interactive Threshold Algorithm Strategy
OBJECTIVE To compare 4 analytic algorithms for interpretation of the Swedish Interactive Threshold Algorithm. INTRODUCTION Analytic algorithms were initially developed for interpretation of standard automated perimetry (using a full threshold strategy). The Swedish interactive threshold algorithm is a novel strategy that was developed to shorten test duration. METHODS One hundred forty-thre...
متن کاملProperties of perimetric threshold estimates from full threshold, ZEST, and SITA-like strategies, as determined by computer simulation.
PURPOSE To investigate the accuracy and precision of threshold estimates returned by two Bayesian perimetric strategies, staircase-QUEST or SQ (a Swedish interactive threshold algorithm [SITA]-like strategy) and ZEST (zippy estimation by sequential testing), and to compare these measures with those of the full-threshold (FT) algorithm. METHODS A computerized visual field simulation model was ...
متن کاملSensitivity to Glaucomatous Visual Field Loss in Full Threshold, Sita Standard, and Sita Fast Tests
Using a newly collected normal database of visual fields obtained with the Swedish Interaction Threshold Algorithm-Standard (SITA-S), SITA Fast, and Full Threshold Programs, inter-subject variability and significance limits for deviation of threshold values were calculated and compared. Average inter-subject variance was 69% smaller with SITA-S and 59% smaller with SITA Fast compared with Full ...