ABR obtained from time-efficient train stimuli for cisplatin ototoxicity monitoring.
نویسندگان
چکیده
BACKGROUND Nonbehavioral methods for identifying cisplatin ototoxicity are important for testing patients with cancer who become too tired or sick to provide a reliable response. The auditory brainstem response (ABR) is a nonbehavioral test that is sensitive to ototoxicity but can be time consuming to implement over a range of frequencies and/or levels. To address this issue, trains of stimuli were developed that offer reliable ABR testing over a range of tone-burst frequencies and levels at a time savings of 77% relative to tone-burst stimuli presented individually. The clinical accuracy of this new method has yet to be determined on a clinical population. PURPOSE This project was designed to determine the test performance of a time-effective ABR methodology aimed at identifying hearing shifts from cisplatin among veterans. A secondary goal was to determine whether improved test performance could be achieved by including our previously developed ototoxicity risk assessment model in the ABR prediction algorithm. RESEARCH DESIGN A set of discriminant functions were derived using logistic regression to model the risk for cisplatin-induced hearing change. Independent variables were one of several ABR metrics alone and combined with an ototoxicity risk assessment model that includes pre-exposure hearing and cisplatin dose. Receiver operating characteristic curve analysis was used to evaluate the test performance of these discriminant functions. STUDY SAMPLE Twenty-two male veterans treated with cisplatin for various cancers provided data from a total of 71 monitoring appointments. DATA COLLECTION AND ANALYSIS Data were collected prospectively from one ear of each participant as designated below. Hearing shift was determined for frequencies within an octave of each patient's high-frequency hearing limit, tested in 1/6th-octave steps. ABRs were monitored using a set of two intensity trains from the highest two multiple frequency tone-burst center frequencies (up to 11.3 kHz) that yielded a robust response at baseline. Each intensity train was presented at 65-105 dB peSPL in 10 dB steps. Scorable ABRs were generally limited to the highest two intensities; therefore, analyses concern those levels. RESULTS The ABR measurement failure was high, up to 52% for some frequencies and levels. Furthermore, the ABR was not frequently obtained at levels below 85 dB peSPL, consistent with previous studies that suggest a stimulus level of greater than 80 dB peSPL is required to obtain a reliable response to trained stimuli. Using multivariate metrics that included the dose-ototoxicity model, the most accurate scoring function was change in amplitude at lowest half-octave frequency obtained at 105 dB (change in wave V amplitude at frequency 2/105). However, absence of wave V at a monitor patient visit of the ABR response at levels 105 or 95 dB peSPL was deemed the preferred scoring function, because it had lower measurement failure and was within one standard error of the most accurate function. CONCLUSIONS Because of the large number of responses that could not be measured at baseline, this technique as implemented holds limited value as an ototoxicity-monitoring method.
منابع مشابه
A Dose-Effect Study of Cisplatin Ototoxicity in Albino Guinea Pigs
Introduction: Cisplatin is one of the most commonly used antineoplastic drugs; nonetheless, its ototoxic dose-limiting side effects have remained a significant challenge in clinical practice. The recognition of the exact template of hearing loss induced by multiple low doses of cisplatin could be of great help in managing the treatment process. The present study aimed to investigate the e...
متن کاملEarly detection of ototoxicity using high-frequency, tone-burst-evoked auditory brainstem responses.
Subjects receiving treatment with ototoxic agents were evaluated concurrently with conventional and high-frequency (> or = 8 kHz) behavioral threshold measures and with ABR to click and to 8, 10, 12, and 14 kHz tone-burst stimuli. Behavioral threshold data revealed ototoxic change in 51 percent of ears evaluated. Of these ears demonstrating behavioral change, 90 percent revealed concurrent ABR ...
متن کاملThe Protective Effect of Cortexin on Cisplatin-Induced Ototoxicity.
OBJECTIVE The aim of this report is to evaluate whether cortexin provides any protective activity against ototoxicity of cisplatin. MATERIALS AND METHODS The study was performed on 30 healthy adult Wistar Albino rats, and rats were randomly divided into three groups of ten. Group I (Control group) was given intraperitoneal (ip) saline solution 1 mL/day. Group II (Cisplatin group) was given ip...
متن کاملCisplatin-Induced Ototoxicity and the Effects of Intratympanic Diltiazem in a Mouse Model.
OBJECTIVE To evaluate whether the calcium-channel blocker diltiazem has protective effects against cisplatin-induced ototoxicity in a mouse model. STUDY DESIGN Original basic science in vivo investigation. SETTING Academic setting: Otolaryngology-Head and Neck Surgery laboratory at University of Connecticut Health Center. SUBJECTS Thirty-nine female CBA/J mice. METHODS Pure tone- or cli...
متن کاملEffects of cisplatin and thiosulfate upon auditory brainstem responses of guinea pigs.
Two side effects which limit the use of cisplatin in cancer chemotherapy are severe nephrotoxicity and ototoxicity. The concurrent administration of sodium thiosulfate with cisplatin reportedly protects from cisplatin nephrotoxicity, however, protection from ototoxicity has not been documented. The purpose of this study was to examine the efficacy of using thiosulfate to ameliorate the ototoxic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 24 9 شماره
صفحات -
تاریخ انتشار 2013