Mathematical modelling of glob-driven tear film breakup.

نویسندگان

  • L Zhong
  • C F Ketelaar
  • R J Braun
  • C G Begley
  • P E King-Smith
چکیده

Evaporation is a recognized contributor to tear film thinning and tear breakup (TBU). Recently, a different type of TBU is observed, where TBU happens under or around a thick area of lipid within a second after a blink. The thick lipid corresponds to a glob. Evaporation alone is too slow to offer a complete explanation of this breakup. It has been argued that the major reason of this rapid tear film thinning is divergent flow driven by a lower surface tension of the glob (via the Marangoni effect). We examine the glob-driven TBU hypothesis in a 1D streak model and axisymmetric spot model. In the model, the streak or spot glob has a localized high surfactant concentration, which is assumed to lower the tear/air surface tension and also to have a fixed size. Both streak and spot models show that the Marangoni effect can lead to strong tangential flow away from the glob and may cause TBU. The models predict that smaller globs or thinner films will decrease TBU time (TBUT). TBU is located underneath small globs, but may occur outside larger globs. In addition to tangential flow, evaporation can also contribute to TBU. This study provides insights about mechanism of rapid thinning and TBU which occurs very rapidly after a blink and how the properties of the globs affect the TBUT.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Tear film analysis and its relation with palpebral fissure height and exophthalmos in Graves' ophthalmopathy].

PURPOSE To evaluate tear film quality by rose bengal staining and its stability by breakup time, relating with palpebral fissure height and exophthalmos in patients with Graves' ophthalmopathy. METHODS We studied 54 eyes of 27 patients with Graves' ophthalmopathy, either in the inflammatory or in the chronic phase of the disease. The evaluation consisted of tear film qualitative analysis by r...

متن کامل

Comparison of Schirmer's test and tear film breakup time test to detect tear film abnormalities in patients with pterygium.

OBJECTIVE To compare tear film breakup time test with Schirmer's test in patients with pterygium. METHODS The case-control study, involving 86 patients with unilateral primary pterygium aged between 30 and 70 years, was conducted at the Department of Ophthalmology, Karachi Medical and Dental College, Abbasi Shaheed Hospital, from May 2009 to December 2010. The eye with pterygium was taken as ...

متن کامل

Dynamics and function of the tear film in relation to the blink cycle.

Great strides have recently been made in quantitative measurements of tear film thickness and thinning, mathematical modeling thereof and linking these to sensory perception. This paper summarizes recent progress in these areas and reports on new results. The complete blink cycle is used as a framework that attempts to unify the results that are currently available. Understanding of tear film d...

متن کامل

Modelling drainage of the precorneal tear film after a blink.

We study the drainage of the precorneal tear film in humans. A fluid dynamic model for the drainage of the aqueous layer is developed that includes the effects of evaporation and gravity. The model may be reduced to a single nonlinear partial differential equation for the thickness of the aqueous layer. The equation is solved numerically and accurate times for film rupture are obtained for phys...

متن کامل

Double lateral shearing interferometer for the quantitative measurement of tear film topography.

A lateral shearing interferometer designed and built for the study of the precorneal tear film topography dynamics and its effect on visual performance is presented. Simple data processing algorithms are discussed and tested on data illustrating different tear topography features: postblink tear undulation, tear breakup, eyelid-produced bumps and ridges, bubbles, and rough precontact lens tear ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Mathematical medicine and biology : a journal of the IMA

دوره   شماره 

صفحات  -

تاریخ انتشار 2018