Early mobilisation after percutaneous cardiac catheterisation using collagen plug (VasoSeal) haemostasis.
نویسندگان
چکیده
OBJECTIVE To assess the efficacy and safety of a haemostatic bovine collagen plug (VasoSeal) in reducing patient immobilisation after cardiac catheterisation from a percutaneous femoral arterial approach. DESIGN A non-randomised, prospective analysis of a new biodegradable haemostatic agent on an intention to treat basis. SETTING The catheterisation suite of a regional cardiothoracic unit. PATIENTS A series of 63 patients having various diagnostic investigations and therapeutic interventions agreed to participate in this study. INTERVENTIONS Cardiac catheterisation was performed from a percutaneous femoral artery approach. Patients taking aspirin and those who required formal anticoagulation were not excluded. Patients were measured for the appropriate sized collagen delivery system at the beginning of the procedure. At the end of the procedure two bovine collagen plugs were applied to the surface of the femoral artery through the channel created by the application device. MAIN OUTCOME MEASURES Incidence of successful delivery, insertion time, immediate outcome, inpatient complications, success of mobilisation of the patient at one and two hours after the procedure, and whether these variables relate to individual patient characteristics. RESULTS Successful placement of the device was achieved in 57 of 63 consecutive patients (90.5%). The mean (SD) insertion time was 86 (24) seconds. Six (9.5%) patients did not receive the haemostat because of femoral artery perforation by the tissue dilator (n = 3), inability to compress the femoral artery proximal to the site of delivery (n = 1), pre-existing haematoma (n = 1), or patient withdrawal from the study (n = 1). Uncomplicated mobilisation within two hours of investigation was possible in 54 of 57 (94.7%) patients receiving this device. A sizeable haematoma (> 5 x 5 cm) prevented early mobilisation in the remaining three patients. Mobilisation was uncomplicated in 32 of 34 (94.1%) patients mobilised at two hours and 22 of 23 (95.6%) at one hour (NS). One patient who was mobilised early without complication later developed evidence of claudication in the treated leg. Femoral arteriography showed a smooth intraluminal filling defect attached to the wall of the femoral artery at the puncture site. This obstruction, presumed to be a collagen plug, was treated successfully with angioplasty. Sheath size, arterial pressure, the use of aspirin, heparin or warfarin, and body mass index did not influence patient outcome. The pattern of complications did not relate to a learning curve experience. CONCLUSIONS The bovine collagen haemostat is a relatively safe and effective device that allows far earlier patient mobilisation than conventional haemostasis after diagnostic and therapeutic interventions from a percutaneous femoral artery approach. These results have important implications for patients undergoing investigation in mobile x ray units or in hospital based day case units.
منابع مشابه
Ambulation three hours after elective cardiac catheterisation through the femoral artery.
OBJECTIVE To test whether very early resumption of ambulation after femoral cardiac catheterisation is feasible and safe in patients with stable symptoms. DESIGN Prospective study in a selected group of men and women undergoing elective cardiac catheterisation, with next day physical inspection. SETTING Inpatient study. SUBJECTS Two hundred consecutive ambulant patients submitted to diagn...
متن کاملPosition and Mobilisation Post-Angiography Study (PAMPAS): a comparison of 4.5 hours and 2.5 hours bed rest.
After cardiac catheterisation, haemostasis is usually achieved by manual compression of the puncture site. The patient is then laid flat, allowed to sit up and then to mobilise—a process taking considerably longer than the procedure itself, and possibly involving more prolonged bed occupancy than is necessary. Well conducted, randomised, controlled trials of patient position (supine or upright)...
متن کاملPredictors of complications associated with closure devices after transfemoral percutaneous coronary procedures.
To purchase reprints, contact The InnoVision Group, 101 Columbia, Aliso Viejo, CA 92656. Phone, (800) 8092273 or (949) 362-2050 (ext 532); fax, (949) 362-2049; e-mail, [email protected]. devices approved by the Food and Drug Administration have replaced manual compression and are associated with decreased length of stay and increased comfort and satisfaction for patients. These devices include ...
متن کاملNetwork Meta-analysis of Randomized Trials on the Safety of Vascular Closure Devices for Femoral Arterial Puncture Site Haemostasis
BACKGROUND Vascular closure devices (VCDs) are widely used to achieve haemostasis after procedures requiring percutaneous common femoral artery (CFA) puncture. There is no consensus regarding the benefits of VCDs, including potential reduction in procedure time, length of hospital stay or time to patient ambulation. No robust evidence exists that VCDs reduce the incidence of puncture site compl...
متن کاملBed rest for preventing complications after transfemoral cardiac catheterisation: a protocol of systematic review and network meta-analysis
BACKGROUND Transfemoral cardiac catheterisation is an invasive medical procedure used for therapeutic or diagnostic purposes. Postoperative bed rest can prevent a number of complications such as bleeding and haematoma formation and can result in side effects such as back pain and urinary discomfort. Currently, there is no consensus regarding the optimal length of bed rest. Our objective is to a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British heart journal
دوره 69 5 شماره
صفحات -
تاریخ انتشار 1993