Quantitation of isoprostane isomers in human urine from smokers and nonsmokers by LC-MS/MS.
نویسندگان
چکیده
A simple, rapid liquid chromatography-tandem mass spectrometry method was developed to identify and quantitate in human urine the isoprostanes iPF(2 alpha)-III, 15-epi-iPF(2 alpha)-III, iPF(2 alpha)-VI, and 8,12-iso-iPF(2 alpha)-VI along with the prostaglandin PGF(2 alpha) and 2,3-dinor-iPF(2 alpha)-III, a metabolite of iPF(2 alpha)-III. Assay specificity, linearity, precision, and accuracy met the required criteria for most analytes. The urine sample storage stability and standard solution stability were also tested. The methodology was applied to analyze 24 h urine samples collected from smokers and nonsmokers on controlled diets. The results for iPF(2 alpha)-III obtained by our method were significantly correlated with results by an ELISA, although an approximately 2-fold high bias was observed for the ELISA data. For iPF(2 alpha)-III and its metabolite 2,3-dinor-iPF(2 alpha)-III, smokers had significantly higher concentrations than nonsmokers (513 +/- 275 vs. 294 +/- 104 pg/mg creatinine; 3,030 +/- 1,546 vs. 2,046 +/- 836 pg/mg creatinine, respectively). The concentration of iPF(2 alpha)-VI tended to be higher in smokers than in nonsmokers; however, the increase was not statistically significant in this sample set. Concentrations of the other three isoprostane isomers showed no trends toward differences between smokers and nonsmokers. Among smokers, the daily output of two type VI isoprostanes showed a weak correlation with the amount of tobacco smoke exposure, as determined by urinary excretion of total nicotine equivalents.
منابع مشابه
Evaluation of Serum Cotinine Cut-Off to Distinguish Smokers From Nonsmokers in the Korean Population
BACKGROUND Cotinine has been widely used as an objective marker to identify current smokers. We conducted this study to address the absence of Korean studies investigating the efficacy of immunoassays and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the detection of serum cotinine and to determine the optimal serum cotinine cut-off level for differentiating current smokers from...
متن کاملQuantitation of urinary volatile nitrosamines from exposure to tobacco smoke.
A sensitive and selective method was developed and validated to detect six volatile nitrosamines (N-nitrosodimethylamine, N-nitrosomethylethylamine, N-nitrosodiethylamine, N-nitrosopiperidine, N-nitrosopyrrolidine and N-nitrosomorpholine) in human urine. This method uses a liquid-liquid extraction cartridge followed by analysis with gas chromatography-tandem mass spectrometry (GC-MS-MS) and qua...
متن کامل15‐F2t‐Isoprostane Concentrations and Oxidant Status in Lactating Dairy Cattle with Acute Coliform Mastitis
BACKGROUND Severe mammary tissue damage during acute coliform mastitis in cattle is partially caused by oxidative stress. Although considered a gold standard biomarker in some human conditions, the utility of 15-F2t-Isoprostanes (15-F2t-Isop) in detecting oxidative stress in dairy cattle has not been validated. HYPOTHESIS Concentrations of 15-F2t-Isop in plasma, urine, and milk correlate with...
متن کاملLC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine
A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS) method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1 × 150 mm, 3.5 μm). The mobile phase was 0.1% formic acid in water and 0.1% formic acid in acetonitrile (50/50, v/v). Linear cal...
متن کاملValidation of self-reported smoking status using saliva cotinine: a rapid semiquantitative dipstick method.
PURPOSE This study evaluated the performance characteristics of a novel rapid method for verifying smoking status in individuals by measurement of cotinine, the primary metabolite of nicotine, in saliva samples using an immunochromatographic strip in a "dipstick" format compared with liquid chromatography/mass spectrometry (LC/MS). MATERIALS AND METHODS A prospective comparison was made of sm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of lipid research
دوره 48 7 شماره
صفحات -
تاریخ انتشار 2007