Resonant microwave cavity for 8.5-12 GHz optically detected electron spin resonance with simultaneous nuclear magnetic resonance.

نویسندگان

  • J S Colton
  • L R Wienkes
چکیده

We present a newly developed microwave resonant cavity for use in optically detected magnetic resonance (ODMR) experiments. The cylindrical quasi-TE(011) mode cavity is designed to fit in a 1 in. magnet bore to allow the sample to be optically accessed and to have an adjustable resonant frequency between 8.5 and 12 GHz. The cavity uses cylinders of high dielectric material, so-called "dielectric resonators," in a double-stacked configuration to determine the resonant frequency. Wires in a pseudo-Helmholtz configuration are incorporated into the cavity to provide frequencies for simultaneous nuclear magnetic resonance (NMR). The system was tested by measuring cavity absorption as microwave frequencies were swept, by performing ODMR on a zinc-doped InP sample, and by performing optically detected NMR on a GaAs sample. The results confirm the suitability of the cavity for ODMR with simultaneous NMR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrically detected magnetic resonance of neutral donors interacting with a two-dimensional electron gas.

We have measured the electrically detected magnetic resonance of donor-doped silicon field-effect transistors in resonant X- (9.7 GHz) and W-band (94 GHz) microwave cavities. The two-dimensional electron gas resonance signal increases by 2 orders of magnitude from X to W band, while the donor resonance signals are enhanced by over 1 order of magnitude. Bolometric effects and spin-dependent scat...

متن کامل

Broadband electron spin resonance at 4-40 GHz and magnetic fields up to 10 T.

A broadband electron spin resonance spectrometer is described which operates at frequencies between 4 and 40 GHz and can be used in superconducting magnets. A tunable cylindrical cavity is connected to a vector network analyzer via coaxial cables, and the radiation is fed into the cavity by a coupling loop. No field modulation is employed. Resonance frequencies below 14 GHz are obtained by inse...

متن کامل

Portable X-band system for solution state dynamic nuclear polarization.

This paper concerns instrumental approaches to obtain large dynamic nuclear polarization (DNP) enhancements in a completely portable system. We show that at fields of 0.35 T under ambient conditions and at X-band frequencies, 1H enhancements of >100-fold can be achieved using nitroxide radical systems, which is near the theoretical maximum for 1H polarization using the Overhauser effect at this...

متن کامل

Enhanced EPR sensitivity from a ferroelectric cavity insert.

We report the development of a simple ferroelectric cavity insert that increases the electron paramagnetic resonance (EPR) sensitivity by an order of magnitude when a sample is placed within it. The insert is a hollow cylinder (length 4.8 mm, outside diameter 1.7 mm, inside diameter 0.6 mm) made from a single crystal of KTaO(3), which has a dielectric constant of 230 at X-band (9.5 GHz). Its ou...

متن کامل

Electrically detected magnetic resonance in a W-band microwave cavity.

We describe a low-temperature sample probe for the electrical detection of magnetic resonance in a resonant W-band (94  GHz) microwave cavity. The advantages of this approach are demonstrated by experiments on silicon field-effect transistors. A comparison with conventional low-frequency measurements at X-band (9.7  GHz) on the same devices reveals an up to 100-fold enhancement of the signal in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 80 3  شماره 

صفحات  -

تاریخ انتشار 2009