Pumping system for the ICARUS 600 ton detector

نویسندگان

  • P. Benetti
  • L. Mazzone
  • C. Montanari
  • M. Rossella
  • C. Vignoli
چکیده

After having analyzed advantages and disadvantages of the possible solutions for the vacuum system for the T600 we estimate in some details the performance a given commercial solution. Pump down times and final vacuum are computed either analytically and with dedicated simulation software. We also estimated the concentration of impurities left in the volume after the cool down and defined some procedures in order to minimize the final contamination of the LAr. Preliminary considerations The design of the pumping system for the T600 has to be based on the following basic considerations. a) The T600 is actually split in two independent volumes of ≈ 300 m each; the two volumes can be evacuated separately in subsequent times using a single pumping system. b) The shape of the basic volume is rather long and narrow and it will contain the readout chambers, which means complicated and long paths for molecules to reach the exit point to the pump; this suggests the use of several pumping points (at least two, if possible 3 or 4) distributed along the structure in order to attain a good and uniform vacuum degree in a reasonable amount of time. c) In order to evacuate and degas the interstices that will be present in the internal detector, molecular regime has to be reached in all parts of the volume; to ensure a vacuum of the order of 10 10 mbar in the small holes and in between the faced flat surfaces (cables, mechanical components of the chambers) a pressure of less than 10 10 mbar has to be set in the gross volume. d) The evacuation time is not, in our case, a critical parameter; we can easily afford one or two weeks of pumping or whatever reasonable amount of time will be required to attain a good outgassing of the internal surfaces. Therefore the pumping speed is not crucial and the evacuation time will be ultimately limited by the time required to degas the surfaces of the internal detector components. Some heating, obtained for example by injecting hot nitrogen in the cooling serpentines or by injecting hot pure Argon in the internal volume, will help to speedup the procedure much more than using faster pumps. e) Due to the large volume to evacuate, the pumping system will have to work for several hours at large pressure; this has to be taken into account when choosing the backing pumps and designing the system layout.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

STATUS OF ICARUS J. RICO for the ICARUS Collaboration a

The ICARUS detector is a liquid argon time projection chamber. It provides three dimensional imaging and calorimetry of ionizing particles over a large volume, with high granularity. Its Physics program includes the study of atmospheric, solar, supernovae and beam neutrinos as well as proton decay searches. The ICARUS technology has reached maturity with the construction and test (during summer...

متن کامل

Solar neutrino events in ICARUS with the new neutron background estimation

New rates of solar neutrinos and background events expected in the 600 ton detector are computed, using the new background measurements performed by the collaboration. The radioactive contamination of the detector materials is higher than expected from tests made in the past. We present in this note the impact of this new background estimation on the solar neutrino analysis with the T600 detect...

متن کامل

Measurement of Through-Going Particle Momentum By Means Of Multiple Scattering With The ICARUS T600 TPC

The ICARUS collaboration has demonstrated, following the operation of a 600 ton (T600) detector at shallow depth, that the technique based on liquid Argon TPCs is now mature. The study of rare events, not contemplated in the Standard Model, can greatly benefit from the use of this kind of detectors. In particular, a deeper understanding of atmospheric neutrino properties will be obtained thanks...

متن کامل

Operation of a 10 m 3 ICARUS detector module

The 10m ICARUS module, used in Pavia until July 1999 for cryogenic and mechanical tests, has been widely modified in order to reflect the final design of the ICARUS 600 t detector. After transportation to the Gran Sasso Laboratory, in February, 2000 it began recording high quality images of long (more than 3m) ionising tracks in the sensitive Argon volume. # 2001 Published by Elsevier Science B.V.

متن کامل

The liquid Argon TPC: a powerful detector for future neutrino experiments and proton decay searches

We discuss the possibility of new generation neutrino and astroparticle physics experiments exploiting the liquid Argon Time Projection Chamber (LAr TPC) technique, following a graded strategy that envisions applications with increasing detector masses (from 100 ton to 100 kton). The ICARUS R&D program has already demonstrated that the technology is mature with the test of the T600 detector at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999