Statistically Evaluating Measurand Alarm Limits when Using Oil Analysis to Monitor Equipment and Oil for Fitness and Contamination

ثبت نشده
چکیده

1.1 This guide provides specific requirements to statistically evaluate measurand alarm thresholds, which are called alarm limits, as they are applied to data collected from in-service oil analysis. These alarm limits are typically used for condition monitoring to produce severity indications relating to states of machinery wear, oil quality, and system contamination. Alarm limits distinguish or separate various levels of alarm. Four levels are common and will be used in this guide, though three levels or five levels can also be used. 1.2 A basic statistical process control technique described herein is recommended to evaluate alarm limits when measurand data sets may be characterized as both parametric and in control. A frequency distribution for this kind of parametric data set fits a well-behaved two-tail normal distribution having a “bell” curve appearance. Statistical control limits are calculated using this technique. These control limits distinguish, at a chosen level of confidence, signal-to-noise ratio for an incontrol data set from variation that has significant, assignable causes. The operator can use them to objectively create, evaluate, and adjust alarm limits. 1.3 A statistical cumulative distribution technique described herein is also recommended to create, evaluate, and adjust alarm limits. This particular technique employs a percent cumulative distribution of sorted data set values. The technique is based on an actual data set distribution and therefore is not dependent on a presumed statistical profile. The technique may be used when the data set is either parametric or nonparametric, and it may be used if a frequency distribution appears skewed or has only a single tail. Also, this technique may be used when the data set includes special cause variation in addition to common cause variation, although the technique should be repeated when a special cause changes significantly or is eliminated. Outputs of this technique are specific measurand values corresponding to selected percentage levels in a cumulative distribution plot of the sorted data set. These percent-based measurand values are used to create, evaluate and adjust alarm limits. 1.4 This guide may be applied to sample data from testing of in-service lubricating oil samples collected from machinery (for example, diesel, pumps, gas turbines, industrial turbines, hydraulics) whether from large fleets or individual industrial applications. 1.5 This guide may also be applied to sample data from testing in-service oil samples collected from other equipment applications where monitoring for wear, oil condition, or system contamination are important. For example, it may be applied to data sets from oil filled transformer and circuit breaker applications. 1.6 Alarm limit evaluating techniques, which are not statistically based are not covered by this guide. Also, the techniques of this standard may be inconsistent with the following alarm limit selection techniques: “rate-of-change,” absolute alarming, multi-parameter alarming, and empirically derived alarm limits. 1.7 The techniques in this guide deliver outputs that may be compared with other alarm limit selection techniques. The techniques in this guide do not preclude or supersede limits that have been established and validated by an Original Equipment Manufacturer (OEM) or another responsible party. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single Base Extension and Fourier-Transform Infra-Red Spectroscopy Techniques; Further Approaches in Discriminating Hazelnut-Adulterated Olive Oil

  Background:Confirmation of olive oil authenticity and particularly virgin olive oil has a great importance. Several advanced chemical and genetic analyses have been used to monitor especial components; however each has its limitations especially when detecting hazelnut-adulterated olive oil. Objectives:The objective of this research is to assess the presence of trace amoun...

متن کامل

Technology transfer strategy in the upstream oil industry (oil fields development) of the Islamic Republic of Iran has provided the effectiveness of technology transfer model

The aim of this research is the determining strategy of technology transfer in the upstream oil industry (oil fields development) of the Islamic Republic of Iran with the use of effective conditional models of technology transfer. In this study, the views and attitudes of 30 managers and experts familiar with the issues of technology transfer, including transfer of technology in the development...

متن کامل

Optimal Detection of Oil Contamination at Sea by the FPSO Algorithm

Leakage of oil from pipelines and oil tankers into seas and oceans is ecologically important and can have significant social and economic impacts on the environment. An early detection of deliberate or accidental oil spills can reduce serious hazards that may threaten coastal residents and help identify pollutants. Iran has been surrounded by seas from the north and the south and they provide u...

متن کامل

A multi-period fuzzy mathematical programming model for crude oil supply chain network design considering budget and equipment limitations

The major oil industry upstream activities include the exploration, drilling, extraction, pipelines installation, and production of crude oil. In this paper, we develop a mathematical model to plan for theseoperations as a crude oil supply chain network design problem.The proposed multi-period mixed integer linear programming model entails both strategic (e.g., facility location and allocation)...

متن کامل

Investigation on metals (V, Ni, and Fe) accumulation in the collection site of oil sludge

The present study investigates the accumulation of vanadium, iron, and nickel in different depths of soil in collection sites of oil sludge, in Masjed Soleyman Oil and Gas Exploitation Company, located in Choob Sorkh Region. To conduct the research, four sampling points have been selected at the mentioned site, with one sampling point chosen outside the site, as the clean area. Soil sampling ha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011