A RealTime HIV-1 viral load assay for automated quantitation of HIV-1 RNA in genetically diverse group M subtypes A-H, group O and group N samples.

نویسندگان

  • Ning Tang
  • Shihai Huang
  • John Salituro
  • Wai-Bing Mak
  • Gavin Cloherty
  • Julie Johanson
  • Yu Hong Li
  • George Schneider
  • John Robinson
  • John Hackett
  • Priscilla Swanson
  • Klara Abravaya
چکیده

The Abbott RealTime HIV-1 assay is an automated test for monitoring HIV-1 viral load in plasma samples. The assay uses reverse transcription polymerase chain reaction (RT-PCR) technology with homogeneous real-time fluorescent detection. Automated sample preparation is performed on the m2000sp instrument where RNA is isolated using magnetic microparticle technology and dispensed to a PCR tray together with the amplification reagents. The PCR tray is then transferred to the Abbott m2000rt instrument for amplification and real-time detection. The assay utilizes two distinct sets of primers and probes for HIV-1 and for internal control (IC). The IC is processed along with each sample to control for sample recovery and inhibition. The HIV-1 primer and probe sequences are targeted to the integrase (IN) region of the polymerase (pol) gene. Due to the selection of a highly conserved target region and a novel, mismatch tolerant probe design, the assay can quantitate HIV-1 group M subtypes A-H, group O, and group N isolates. The assay provides high reproducibility and a wide dynamic range, allowing quantitation from 40 copies to 10 million copies of HIV-1 RNA per milliliter of plasma. HIV-1 RNA concentrations detected with 95% probability were 25copies/mL with 1.0mL of plasma, 39copies/mL with 0.6mL of plasma, 65copies/mL with 0.5mL of plasma, and 119copies/mL with 0.2mL of plasma.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative performance of three viral load assays on human immunodeficiency virus type 1 (HIV-1) isolates representing group M (subtypes A to G) and group O: LCx HIV RNA quantitative, AMPLICOR HIV-1 MONITOR version 1.5, and Quantiplex HIV-1 RNA version 3.0.

The performance of the LCx HIV RNA Quantitative (LCx HIV), AMPLICOR HIV-1 MONITOR version 1.5 (MONITOR v1.5), and Quantiplex HIV-1 RNA version 3.0 (bDNA v3.0) viral load assays was evaluated with 39 viral isolates (3 A, 7 B, 6 C, 4 D, 8 E, 4 F, 1 G, 4 mosaic, and 2 group O). Quantitation across the assay dynamic ranges was assessed using serial fivefold dilutions of the viruses. In addition, se...

متن کامل

Use of calibrated viral load standards for group M subtypes of human immunodeficiency virus type 1 to assess the performance of viral RNA quantitation tests.

Optimal management of human immunodeficiency virus type 1 (HIV-1) disease requires accurate quantitation of viral RNA concentrations in plasma. Evidence for increasing geographic intermixing of HIV-1 subtypes makes equivalent quantitation of all subtypes essential. The performances of six quantitative viral RNA tests are described, for the first time, with calibrated viral isolates of diverse s...

متن کامل

Design and evaluation of a human immunodeficiency virus type 1 RNA assay using nucleic acid sequence-based amplification technology able to quantify both group M and O viruses by using the long terminal repeat as target.

Currently available human immunodeficiency virus type 1 (HIV-1) RNA quantification assays can detect most viruses of the group M subtypes, but a substantial number are missed or not quantified reliably. Viruses of HIV-1 group O cannot be detected by any commercially available assay. We developed and evaluated a quantitative assay based on nucleic acid sequence-based amplification (NASBA) techno...

متن کامل

Evaluation of performance of the Gen-Probe human immunodeficiency virus type 1 viral load assay using primary subtype A, C, and D isolates from Kenya.

Accurate and sensitive quantification of human immunodeficiency virus type 1 (HIV-1) RNA has been invaluable as a marker for disease prognosis and for clinical monitoring of HIV-1 disease. The first generation of commercially available HIV-1 RNA tests were optimized to detect the predominant HIV-1 subtype found in North America and Europe, subtype B. However, these tests are frequently suboptim...

متن کامل

Analytical Performances of Human Immunodeficiency Virus Type 1 RNA-Based Amplix® Real-Time PCR Platform for HIV-1 RNA Quantification

Objectives. We evaluated the performances of Amplix real-time PCR platform developed by Biosynex (Strasbourg, France), combining automated station extraction (Amplix station 16 Dx) and real-time PCR (Amplix NG), for quantifying plasma HIV-1 RNA by lyophilized HIV-1 RNA-based Amplix reagents targeting gag and LTR, using samples from HIV-1-infected adults from Central African Republic. Results. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of virological methods

دوره 146 1-2  شماره 

صفحات  -

تاریخ انتشار 2007