Vicarious Calibration of Meris over Dark Waters in the near Infrared

نویسنده

  • Richard Santer
چکیده

We propose to evaluate the calibration of MERIS (Medium Resolution Imaging Spectrometer) over dark waters in the near infrared. We work with five months of data, from July to November 2003, over five world sites: Venice and Lampedusa in Italy, El Arenosillo in Spain, MOBY/Lanai and CalCOFI/San Nicolas in United States. The sites are all equipped with a CIMEL station that forms part of the AERONET network. The basic idea is to associate CIMEL sky radiance measurements with MERIS level 1b data in a twin geometry which corresponds to the same scattering angle. This vicarious calibration relies on an accurate description of the atmospheric scattering based on the CIMEL measurements. After a selection of MERIS and CIMEL data we finally obtained 8 days for the calibration task – about 10% of the initial dataset. We achieved a match-up analysis at 6 MERIS wavelengths, from 884 nm to 664 nm, in the near infrared (NIR). Results show an agreement between the onboard calibration and our method within 1.5% in the NIR which falls in the expected accuracy of the two methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiative Transfer Code Comparison for Meris Vicarious Calibration

Different groups are involved in the MERIS vicarious activities. Most of the time, the prediction of the incoming radiance to the sensor needs radiative transfer computations. An inter comparison exercise is reported here based on radiative transfer computations with different codes applied on suitable test cases for vicarious calibration. Because the top of atmosphere signal over bright target...

متن کامل

Status on the Implementation of the Bpac

The Bright Pixel Atmospheric Correction (BPAC) is the MERIS operational algorithm for precorrecting the residual marine signal in the near infrared prior to the Clear water atmospheric correction. It is an essential step in the mission for computing Level 2 products on Case 2 waters. It is also always applied on Case 1 waters. The method is based on an iterative coupling between a simplified at...

متن کامل

MERIS / ENVISAT Vicarious Calibration Results at Railroad Valley Playa (NV)*

On August 22, 2002, a vicarious calibration (VC) experiment of MERIS, a pushbroom imaging spectrometer on ESA’s ENVISAT, was performed. The purpose of this experiment was the acquisition of in-situ measurements of surface and atmospheric conditions over a bright, uniform target. These data were then used to compute top-ofatmosphere (TOA) radiances, which were correlated with the MERIS TOA radia...

متن کامل

Long-term Meris Land Product Accuracy Assessment Based on Vicarious Calibration and Regional Validation

Since the launch of MERIS on board of ENVISAT long term activities using vicarious calibration approaches have been set in place to monitor potential drifts in the calibration of the radiance products of MERIS. In this paper, a stable and well monitored reference calibration site named Railroad Valley Playa (Nevada, USA) is used to derive the calibration uncertainties of the MERIS FR TOA radian...

متن کامل

In-Orbit Radiometric Calibration and Stability Monitoring of the PROBA-V Instrument

Since its launch in May 2013, the in-orbit radiometric performance of PROBA-V has been continuously monitored. Due to the absence of on-board calibration devices, in-flight performance monitoring and calibration relies fully on vicarious calibration methods. In this paper, the multiple vicarious calibration techniques used to verify radiometric accuracy and to perform calibration parameter upda...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004