Direct modulation of the effective sensitivity of a CCD detector: a new approach to time-resolved fluorescence imaging.

نویسندگان

  • A C Mitchell
  • J E Wall
  • J G Murray
  • C G Morgan
چکیده

In this paper a novel approach to frequency-domain fluorescence lifetime imaging (FLIM) is described. In a CCD camera a single pixel is defined by a charge pattern on a group of electrodes. By modulation of the pattern of voltages defining the pixel structure it is possible to modulate the sensitivity of the CCD at radio frequency. The modulation enhances the noise performance of the CCD, in contrast to the deterioration in performance seen when an intensifier stage is similarly modulated. The new technology has potential applications to a wide range of assays as well as in conventional FLIM applications. Unlike intensifier-based systems, the directly modulated CCD is physically small, inexpensive, robust and offers superior resolution and noise performance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling Time Resolved Light Propagation Inside a Realistic Human Head Model

Background: Near infrared spectroscopy imaging is one of the new techniques used for investigating structural and functionality of different body tissues. This is done by injecting light into the medium and measuring the photon intensity at the surface of the tissue.Method: In this paper the different medical applications, various imaging and simulation techniques of NIRS imaging is described. ...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

Quantitative Comparison of Analytical solution and Finite Element Method for investigation of Near-Infrared Light Propagation in Brain Tissue Model

Introduction: Functional Near-Infrared Spectroscopy (fNIRS) is an imaging method in which light source and detector are installed on the head; consequently, re-emission of light from human skin contains information about cerebral hemodynamic alteration. The spatial probability distribution profile of photons penetrating tissue at a source spot, scattering into the tissue, and being released at ...

متن کامل

کاهش ولتاژ وجه مشترک در مبدل ماتریسی با حذف بردار صفر

Matrix Converter (MC) is a direct energy conversion device with high input power factor. In the Direct Matrix Converter modulation, the Space Vector Modulation (SVM) method by simultaneous control of the input current and output voltage is used. In this method sum of the phase voltages in the central point of load is nonzero, then nonzero Common-Mode Voltage (CMV) in central point is produce...

متن کامل

A Comprehensive Performance Analysis of Direct Detection Receivers inWDMASystems

In this work the performance of a wavelength division multiple access (WDMA) system with direct detection receiver is investigated. For this purpose, the probability of error in a WDMA network with OOK modulation considering crosstalk, ISI, photo detector noise and thermal noise is calculated and the effect of each on system performance is investigated. The system performance in presence of PIN...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of microscopy

دوره 206 Pt 3  شماره 

صفحات  -

تاریخ انتشار 2002