Optimization of tomotherapy treatment planning for patients with bilateral hip prostheses

نویسندگان

  • David Chapman
  • Shaun Smith
  • Rob Barnett
  • Glenn Bauman
  • Slav Yartsev
چکیده

BACKGROUND To determine the effect of different imaging options and the most efficient imaging strategy for treatment planning of patients with hip prostheses. METHODS The planning kilovoltage CT (kVCT) and daily megavoltage CT (MVCT) studies for three prostate cancer patients with bilateral hip prostheses were used for creating hybrid kVCT/MVCT image sets. Treatment plans were created for kVCT images alone, hybrid kVCT/MVCT images, and MVCT images alone using the same dose prescription and planning parameters. The resulting dose volume histograms were compared. The orthopedic metal artifact reduction (O-MAR) reconstruction tool for kVCT images and different MVCT options were investigated with a water tank fit with double hip prostheses. Treatment plans were created for all imaging options and calculated dose was compared with the one measured by a pin-point ion chamber. RESULTS On average for three patients, the D35% for the bladder was 8% higher in plans based on MVCT images and 7% higher in plans based on hybrid images, compared to the plans based on kVCT images alone. Likewise, the D35% for the rectum was 3% higher than the kVCT based plan for both hybrid and MVCT plans. The average difference in planned D99% in the PTV compared to kVCT plans was 0.9% and 0.1% for MVCT and hybrid plans, respectively. For the water tank with hip prostheses phantom, the kVCT plan with O-MAR correction applied showed better agreement between the measured and calculated dose than the original image set, with a difference of -1.9% compared to 3.3%. The measured doses for the MVCT plans were lower than the calculated dose due to image size limitations. The best agreement was for the kVCT/MVCT hybrid plans with the difference between calculated and measured dose around 1%. CONCLUSION MVCT image provides better visualization of patient anatomy and hybrid kVCT/MVCT study enables more accurate calculations using updated MVCT relative electron density calibration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Megavoltage CT images of helical tomotherapy unit for radiation treatment simulation: impact on feasibility of treatment planning in a prostate cancer patient with bilateral femoral prostheses.

Metal prosthesis artefacts on CT images can be a significant problem in the definition of volumes of interest, dose calculation and patient setup in modern radiotherapy. We experienced considerable difficulties in defining the organs at risk and treatment volumes on kVCT images of standard CT simulation in a prostate cancer patient due to the presence of bilateral femoral prostheses causing art...

متن کامل

Is helical tomotherapy-based intensity-modulated radiotherapy feasible and effective in bilateral synchronous breast cancer? A two-center experience.

PURPOSE This study describes the early clinical results and dosimetric parameters of intensity-modulated radiation therapy (IMRT) using a tomotherapy device in patients with primary bilateral synchronous breast cancer (PSBBC). METHODS Fourteen patients with bilateral breast cancer were treated with tomotherapy between January 2011 and October 2014. The treatment planning objectives were to co...

متن کامل

Conversion of helical tomotherapy plans to step-and-shoot IMRT plans--Pareto front evaluation of plans from a new treatment planning system.

PURPOSE The resulting plans from a new type of treatment planning system called SharePlan have been studied. This software allows for the conversion of treatment plans generated in a TomoTherapy system for helical delivery, into plans deliverable on C-arm linear accelerators (linacs), which is of particular interest for clinics with a single TomoTherapy unit. The purpose of this work was to eva...

متن کامل

Dependency issues in survival analyses of 55,782 primary hip replacements from 47,355 patients.

Artificial hip joints are used in only one hip for about 85 per cent of the patients and in both hips (bilateral) for about 15 per cent of the patients. The occurrence of bilateral prostheses and the influence they have in survival analyses of joint arthroplasties are seldom considered. In this study we therefore focus on issues related to bilateral primary hip prostheses, time to revision surg...

متن کامل

Helical tomotherapy planning for left-sided breast cancer patients with positive lymph nodes: comparison to conventional multiport breast technique.

PURPOSE To evaluate the feasibility of using helical tomotherapy for locally advanced left-sided breast cancer. METHODS AND MATERIALS Treatment plans were generated for 10 left-sided breast cancer patients with positive lymph nodes comparing a multiport breast (three-dimensional) technique with the tomotherapy treatment planning system. The planning target volumes, including the chest wall/br...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014