Microbiologic profile of flexible endoscope disinfection in two Brazilian hospitals.

نویسندگان

  • Alexandre P Machado
  • Ana Teresa Mancini Pimenta
  • Paulo P Contijo
  • Stephan Geocze
  • Olga Fischman
چکیده

BACKGROUND [corrected] Endoscopes are routinely used in hospitals and clinics of the world and they can be potential sources of cross-infection when the decontamination process is unsuitable AIM The routines of flexible endoscope (bronchoscopes, esophagogastroduodenoscopes and colonoscopes) disinfection procedures used in two Brazilian university hospitals were evaluated during a 3-year period METHODS Aleatory samples from internal channels of endoscopes were collected after patient examination and after cleaning/disinfection procedures RESULTS A contamination >3 log10 was achieved in samples recovered from endoscopes after patient examination. These samples yielded gram-negative bacilli (n = 142: 56%), gram-positive cocci (n = 43: 17%), yeast cells (n = 43: 17%), and gram-positive bacilli (n = 26: 10%). Approximately, 72 out of 149 samples (48.32%) collected after undergoing the cleaning and disinfection procedures disclosed gram-negative bacilli (n = 55: 61%), gram-positive cocci (n = 21: 23%), gram-positive bacilli (n = 8: 9%) and yeast cells (n = 6: 7%). Esophagogastroduodenoscopes and colonoscopes were the most frequently contaminated devices. Pseudomonas aeruginosa, Klebsiella pneumoniae, Escherichia coli, Enterobacter spp, Serratia marcescens, Proteus mirabilis, Citrobacter freundii, Staphylococcus aureus, Staphylococcus coagulase negative, Micrococcus luteus, Candida albicans, C. tropicalis, C. glabrata, C. guilliermondii, Bacillus spp and Corynebacterium spp were predominantly identified CONCLUSION Inappropriate cleaning and low times of disinfection were respectively the major factors associated with the presence of microorganisms in colonoscopes and esophagogastroduodenoscopes. By analyzing the identified germs, hospital disinfection was considered of either intermediate or poor level. After this investigation, both university centers improved their previous protocols for disinfection and conditions for reprocessing endoscopes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

WHO EMRO | Reprocessing practices for gastrointestinal endoscopes: a multicentre study in Egyptian university hospitals PDF version Short communication

The aim of this study was to assess the practices of health care workers during gasterointestinal endoscope reprocessing, evaluate their knowledge about reprocessing, and verify their compliance with laboratory and microbiological tests in endoscopy units at Zagazig University and Fayoum University hospitals. All nursing staff on duty from 10 endoscopy units, with 16 flexible endoscopes, were i...

متن کامل

Reprocessing practices for gastrointestinal endoscopes: a multicentre study in Egyptian university hospitals.

The aim of this study was to assess the practices of health care workers during gasterointestinal endoscope reprocessing, evaluate their knowledge about reprocessing, and verify their compliance with laboratory and microbiological tests in endoscopy units at Zagazig University and Fayoum University hospitals. All nursing staff on duty from 10 endoscopy units, with 16 flexible endoscopes, were i...

متن کامل

Current Status of Endoscope Reprocessing in Korea

(GI) endoscopy has been widely used as a clinical diagnostic procedure in Korea since the introduction of the National Cancer Screening Program in 1999. Moreover, the use of endoscopic procedures to treat GI disorders is increasing rapidly. A review article published in 1993 reported 281 instances of pathogen transmission attributed to GI en-doscopy between 1966 and 1992. 1 A recent review foun...

متن کامل

Superbugs on Duodenoscopes: the Challenge of Cleaning and Disinfection of Reusable Devices.

Inadequate flexible endoscope reprocessing has been associated with infection outbreaks, most recently caused by carbapenem-resistant Enterobacteriaceae. Lapses in essential device reprocessing steps such as cleaning, disinfection/sterilization, and storage have been reported, but some outbreaks have occurred despite claimed adherence to established guidelines. Recommended changes in these guid...

متن کامل

Role of Clinical Endoscopy in Emphasizing Endoscope Disinfection

Based on the unexpected Middle East respiratory syndrome (MERS) outbreak in Korea, it was established that the virus can spread easily, MERS exposure in hospitals carries an extreme risk for infection as well as mortality, and the sharing of information was essential for infection control. Although the incidence of exogenous infections related to contaminated endoscopes is very low, the majorit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos de gastroenterologia

دوره 43 4  شماره 

صفحات  -

تاریخ انتشار 2006