Metrological triangle for measurements of isotope amount ratios of silver, indium, and antimony using multicollector-inductively coupled plasma mass spectrometry: the 21st century Harvard method.

نویسندگان

  • Lu Yang
  • Ralph E Sturgeon
  • Zoltán Mester
  • Juris Meija
چکیده

The calibration of measurements of the isotope amount ratio using a log-linear regression method with multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS) is the latest development in isotope amount ratio metrology. This calibration method, however, is often met with criticism. In this work, we evaluate the robustness of this calibration strategy wherein measurements of antimony and indium isotope amount ratios are calibrated against the isotope amount ratio of silver, despite the significant difference in their atomic mass. In addition, a metrological triangle comprising Ag-Sb-In measurement results is constructed from three pairs of interelemental isotope amount ratio calibrations: N((121)Sb)/N((123)Sb) from the N((107)Ag)/N((109)Ag) of NIST SRM 978a measurement standard, N((113)In)/N((115)In) from the N((121)Sb)/N((123)Sb), and then calibration of N((107)Ag)/N((109)Ag) from the obtained N((113)In)/N((115)In) measured ratio values to verify consistency with the known N((107)Ag)/N((109)Ag). This calibration method revives one of the salient features of the classical "Harvard method", a network of relationships among the isotopic compositions of various elements. The atomic weights of antimony and indium, reported here for the first time using MC-ICPMS, 121.7590(22)(k=2) and 114.818 27(35)(k=2), are in good agreement with their current standard atomic weights. In addition, this study provides the first calibrated mass spectrometric isotope amount ratio measurements for indium.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Cu Purification Using an Extraction Resin for Determination of Isotope Ratios by Multicollector ICP-MS

A new simple and quick method has been established for separation of Cu from solutions using an extraction chromatographic resin utilizing Aliquat 336 (commercially available as TEVATM resin) and Cu(I). This method involves the use of a one milliliter column containing 0.33 mL TEVATM resin on 0.67 mL Amberchrom CG-71C acrylic resin. Copper was adsorbed on the column by forming Cu(I) with 0.15% ...

متن کامل

Strontium isotope ratios (87Sr/86Sr) of tooth enamel: a comparison of solution and laser ablation multicollector inductively coupled plasma mass spectrometry methods.

Strontium isotope ratios (87Sr/86Sr) in tooth enamel provide a means to investigate migration and landscape use in humans and other animals. Established methods for measuring (87)Sr/(86)Sr in teeth use bulk sampling (5-20 mg) and labor-intensive elemental purification procedures before analysis by either thermal ionization mass spectrometry (TIMS) or multicollector inductively coupled plasma ma...

متن کامل

Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr

This paper critically reviews the state-of-the-art of isotope amount ratio measurements by solution-based multi-collector inductively coupled plasma mass spectrometry (MC ICP-MS) and presents guidelines for corresponding data reduction strategies and uncertainty assessments based on the example of n((87)Sr)/n((86)Sr) isotope ratios. This ratio shows variation attributable to natural radiogenic ...

متن کامل

Invited review article: Recent developments in isotope-ratio mass spectrometry for geochemistry and cosmochemistry.

Mass spectrometry is fundamental to measurements of isotope ratios for applications in isotope geochemistry, geochronology, and cosmochemistry. Magnetic-sector mass spectrometers are most common because these provide the best precision in isotope ratio measurements. Where the highest precision is desired, chemical separation followed by mass spectrometric analysis is carried out with gas (noble...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 82 21  شماره 

صفحات  -

تاریخ انتشار 2010