MRI-related static magnetic stray fields and postural body sway: a double-blind randomized crossover study.

نویسندگان

  • Lotte E van Nierop
  • Pauline Slottje
  • Herman Kingma
  • Hans Kromhout
چکیده

We assessed postural body sway performance after exposure to movement induced time-varying magnetic fields in the static magnetic stray field in front of a 7 Tesla (T) magnetic resonance imaging scanner. Using a double blind randomized crossover design, 30 healthy volunteers performed two balance tasks (i.e., standing with eyes closed and feet in parallel and then in tandem position) after standardized head movements in a sham, low exposure (on average 0.24 T static magnetic stray field and 0.49 T·s(-1) time-varying magnetic field) and high exposure condition (0.37 T and 0.70 T·s(-1)). Personal exposure to static magnetic stray fields and time-varying magnetic fields was measured with a personal dosimeter. Postural body sway was expressed in sway path, area, and velocity. Mixed-effects model regression analysis showed that postural body sway in the parallel task was negatively affected (P < 0.05) by exposure on all three measures. The tandem task revealed the same trend, but did not reach statistical significance. Further studies are needed to investigate the possibility of independent or synergetic effects of static magnetic stray field and time-varying magnetic field exposure. In addition, practical safety implications of these findings, e.g., for surgeons and others working near magnetic resonance imaging scanners need to be investigated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...

متن کامل

بررسی میزان مواجهه شغلی با میدان های مغناطیسی پایا واثرات بهداشتی آن در مراکز تصویر برداری تشدید مغناطیسی

 Background and aim:  Magnetic resonance imaging as one of the best medical scanning technique is considered to be the most important sources of static magnetic fields. The staffs of MRI ´s units frequently exposed to these static magnetic fields. This study aims to determine the occupational exposure level to mentioned field and its related health effects in MRI´s units.    Methods:  The occup...

متن کامل

The Effect of Repetitive Transcranial Magnetic Stimulation on Postural Stability After Acute Stroke: A Clinical Trial

Introduction: Balance impairment is a common problem and a major cause of motor disability after stroke. Therefore, this study aimed to investigate whether low-frequency repetitive Transcranial Magnetic Stimulation (rTMS) improves the postural balance problems in stroke patients. Methods: This randomized double blind clinical trial with 12 weeks follow-up was conducted on stroke patients. Trea...

متن کامل

Effect of postural insoles on static and functional balance in children with cerebral palsy: A randomized controlled study

BACKGROUND Improved gait efficiency is one of the goals of therapy for children with cerebral palsy (CP). Postural insoles can allow more efficient gait by improving biomechanical alignment. OBJECTIVE The aim of the present study was to determine the effect of the combination of postural insoles and ankle-foot orthoses on static and functional balance in children with CP. METHOD A randomize...

متن کامل

Occupational exposure of healthcare and research staff to static magnetic stray fields from 1.5–7 Tesla MRI scanners is associated with reporting of transient symptoms

OBJECTIVES Limited data is available about incidence of acute transient symptoms associated with occupational exposure to static magnetic stray fields from MRI scanners. We aimed to assess the incidence of these symptoms among healthcare and research staff working with MRI scanners, and their association with static magnetic field exposure. METHODS We performed an observational study among 36...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 70 1  شماره 

صفحات  -

تاریخ انتشار 2013