Influence of DNA target melting behavior on real-time PCR quantification.
نویسندگان
چکیده
BACKGROUND Quantitative real-time PCR is increasingly used to quantify copy numbers of nucleic acids for clinical applications. We observed that the measurements of allele imbalances of the tumor suppressor gene p16 and the oncogene ErbB-2 yielded results with variable precision under certain experimental conditions. METHODS We used the LightCycler(TM) real-time PCR system to quantify different genomic target sequences using hybridization probes or SYBR Green for detection. RESULTS With two primer/template systems (p16 and ErbB-2), we observed sinusoidal scattering of the threshold cycle values depending on the capillary position in the thermostated reaction chamber. This scattering depended on the denaturation temperature only when complete genomic DNA was used as template and did not occur when PCR product or restricted or boiled genomic DNA was used or the denaturation temperature in the first cycles was increased (and other targets, such as p53, HBB, IGF-1, GAPDH, and PBGD, did not show this behavior). CONCLUSIONS Before a primer system is used for precise quantitative real-time PCR, the dependence of the quantification results on the positions of reaction tubes in the thermocycler should be tested. Our data indicate that amplification efficiencies, especially in the first cycles, depend not only on the priming efficiencies of the primers and the melting temperature of the amplicon, but also on the melting behavior of the amplicon's genomic vicinity. Complete denaturation of genomic DNA is necessary to maximize precision of quantitative PCR. Higher denaturation temperatures in the initial cycles or boiling of DNA before the PCR can improve the accuracy of quantification in some cases.
منابع مشابه
Quantification and Optimization of Candida albicans DNA in Blood Samples Using Real- Time PCR
Background: Candida albicans (C. albicans) is a major cause of candidaemia in people with impaired immunity. Blood culture is a “gold standard” for candidaemia detection but is time-consuming and relatively insensitive. We established a real-time PCR assay for C. albicans detection in blood by LightCycler PCR and melting curve analysis. Methods: Five milliliter blood samples from...
متن کاملRapid competitive PCR using melting curve analysis for DNA quantification.
A rapid competitive PCR method was developed to quantify DNA on the LightCycler. It rests on the quantitative information contained in the melting curves obtained after amplification in the presence of SYBR Green I. Specific hybridization probes are not required. Heterologous internal standards sharing the same primer binding sites and having different melting temperatures to the natural PCR pr...
متن کاملMisleading glycated hemoglobin results in a patient with hemoglobin SC disease.
References 1. Wilhelm J, Hahn M, Pingoud A. Influence of DNA target melting behavior on real-time PCR quantification. Clin Chem 2000;46:1738–43. 2. Zuna J, Muzikova K, Madzo J, Krejci O, Trka J. Temperature non-homogeneity in rapid airflowbased cycler significantly affects real-time PCR. Biotechniques 2002;33:508–12. 3. Schneider M, Joncourt F, Sanz J, von Kanel T, Gallati S. Detection of exon ...
متن کاملIdentification and Quantification of Celery Allergens Using Fiber Optic Surface Plasmon Resonance PCR
Abstract: Accurate identification and quantification of allergens is key in healthcare, biotechnology and food quality and safety. Celery (Apium graveolens) is one of the most important elicitors of food allergic reactions in Europe. Currently, the golden standards to identify, quantify and discriminate celery in a biological sample are immunoassays and two-step molecular detection assays in wh...
متن کاملSingle-channel multiplexing without melting curve analysis in real-time PCR
Multiplex real-time PCR with quantification of targets in a single fluorescence channel has been the demand in biotechnology industry. Here, we develop a novel analytical real-time PCR technique to detect multiple targets in a single fluorescence channel without melting curve analysis. In this technique, we show the intensity of the fluorescence signals of two discrete Tm targets is different a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 46 11 شماره
صفحات -
تاریخ انتشار 2000