Comparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation.

نویسندگان

  • Tyler S Lamb
  • Amar Thakrar
  • Mahua Ghosh
  • Merne P Wilson
  • Thomas W Wilson
چکیده

OBJECTIVE To compare blood pressure readings obtained with two commonly used oscillometric monitors: Omron HEM 711 AC (OM) and Welch-Allyn 52000 series NIBP/oximeter (WA) with mercury sphygmomanometers (Merc) in subjects with atrial fibrillation. METHODS We recruited 51 hemodynamically stable subjects with atrial fibrillation. Fifty four subjects in normal sinus rhythm served as controls. Supine blood pressure readings in each arm were recorded simultaneously using one monitor and Merc. The second monitor then replaced the first and readings were repeated. Merc was then switched to the opposite arm, and both monitors retested. Apical heart rates were ascertained with a stethoscope. We used the averaged, same arm Merc readings as "gold standard". RESULTS Automated blood pressure readings were obtained in all control subjects and in all but three of those with atrial fibrillation. Both monitors, and operators, noted a difference between apical and radial/brachial pulse rates: apical-recorded: Merc 6.1 + or - 15.0; OM 5.5 + or - 13.7; WA 10.0 + or - 21.2 beats per minute. Both monitors were accurate in controls: over 90% of readings were within 10 mmHg of averaged Merc, and both achieved European Hypertension Society standards. In subjects with atrial fibrillation, about one quarter of all oscillometric readings differed from Merc by more than 10 mmHg. Both falsely high and falsely low readings occurred, some up to 30 mmHg. There was no relation between accuracy and heart rate. CONCLUSIONS Single blood pressure readings, taken with oscillometric monitors in subjects with atrial fibrillation differ, often markedly, from those taken manually. Health care professionals should record multiple readings manually, using validated instruments when making therapeutic decisions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of atrial fibrillation on the accuracy of oscillometric blood pressure monitoring.

The introduction of automated oscillometric blood pressure monitors was the basis for today's widespread use of blood pressure self-measurement. However, in atrial fibrillation, there is a controversial debate on the use of oscillometry because there is a high variability of heart rate and stroke volume. To date, the accuracy of oscillometric blood pressure monitoring in atrial fibrillation has...

متن کامل

Accuracy of oscillometric blood pressure monitors for the detection of atrial fibrillation: a systematic review.

Atrial fibrillation (AF) is a significant risk factor for stroke and early detection of AF may help to identify patients in need of treatment. Automated blood pressure (BP) monitors with implemented AF or arrhythmia detection systems may be a useful tool for early diagnosis of AF. A systematic review (Medline/PubMed, Embase, Cochrane) of studies was performed to assess the accuracy of modified ...

متن کامل

Comparison of aneroid and oscillometric blood pressure measurements in children.

Limited data exist on the comparison of blood pressure (BP) measurements using aneroid and oscillometric devices. The purpose of the study was to investigate the difference in BP obtained using oscillometric and aneroid BP monitors in 9- to 10-year-old children. A total of 979 children were divided into group O, which underwent two oscillometric BP readings followed by two aneroid readings, and...

متن کامل

Comparison of methods of automatic blood pressure measurement in the same device

Comparison of tacho-oscillographic and oscillometric methods for human blood pressure measurement with cuff occlusion in the same device at the same time is described. For this purpose the measurement system and software for signal processing that realize these methods in the same device was developed. Experiment shows that oscillometric method with photoplethysmographic (PPG) sensors does not ...

متن کامل

Accuracy of pulse interval timing in ambulatory blood pressure measurement

Blood pressure (BP) monitors rely on pulse detection. Some blood pressure monitors use pulse timings to analyse pulse interval variability for arrhythmia screening, but this assumes that the pulse interval timings detected from BP cuffs are accurate compared with RR intervals derived from ECG. In this study we compared the accuracy of pulse intervals detected using an ambulatory blood pressure ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical and investigative medicine. Medecine clinique et experimentale

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 2010